Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

A novel, fast responding, low noise potentiometric sensor containing a carbon-based polymeric membrane for measuring surfactants in industrial and environmental applications (CROSBI ID 232364)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Samardžić, Mirela ; Galović, Olivera ; Hajduković, Mateja ; Sak-Bosnar, Milan A novel, fast responding, low noise potentiometric sensor containing a carbon-based polymeric membrane for measuring surfactants in industrial and environmental applications // Talanta, 162 (2017), 316-323. doi: 10.1016/j.talanta.2016.10.041

Podaci o odgovornosti

Samardžić, Mirela ; Galović, Olivera ; Hajduković, Mateja ; Sak-Bosnar, Milan

engleski

A novel, fast responding, low noise potentiometric sensor containing a carbon-based polymeric membrane for measuring surfactants in industrial and environmental applications

A new high-sensitivity potentiometric sensor for anionic surfactants was fabricated using the dimethyldioctadecylammonium-tetraphenylborate (DDA-TPB) ion associate as an ionophore that was incorporated into a liquid PVC membrane. Carbon powder was used for immobilization of the ionophore in the membrane, thus significantly reducing its ohmic resistance and reducing its signal drift. The sensor exhibits a sub-Nernstian response for both dodecylbenzenesulfonate (DBS) and dodecyl sulfate (DS) in H2O (55.3 and 58.5 mV/decade of activity, respectively) in a range between 3.2×10−7 and 4.6×10−3 M for DS and 2.5×10−7 and 1.2×10−3 M for DBS. The sensor also exhibited a sub-Nernstian response for DS and DBS in 10 mM Na2SO4 (55.4 and 57.7 mV/decade of activity, respectively) between 2.5×10−7 and 4.6×10−3 M for DS and 1.5×10−7 and 8.8×10−4 M for DBS. The detection limits for DS and DBS in H2O were 2.5×10−7 and 2.0×10−7 M and in 10 mM Na2SO4 the detection limits were 2.5×10−7 and 1.2×10−7 M, respectively. The response time of the sensor was less than 5 s for changes at higher concentration levels (above 1×10−4 M) in both water and 10 mM Na2SO4. At lower concentrations (below 1×10−5 M) the response times were 8 and 6 s in water and 10 mM Na2SO4, respectively. The signal drift of the sensor was 1.2 mV/hour. The new carbon-based sensor exhibited excellent selectivity performance for DS over almost all of the anions commonly present in commercial formulations and it was successfully employed as an end-point detector in potentiometric titrations of anionic surfactants in a pH range from 3 to 12. Three-component mixtures containing sodium alkanesulfonate (C10, C12 and C14) were successfully differentially titrated.

carbon powder ; anionic surfactant sensor ; potentiometric titration ; industrial products ; effluents

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

162

2017.

316-323

objavljeno

0039-9140

1873-3573

10.1016/j.talanta.2016.10.041

Povezanost rada

Kemija

Poveznice
Indeksiranost