Use of GOTHIC Code for Assessment of Equipment Environmental Qualification (CROSBI ID 465262)
Prilog sa skupa u zborniku | izvorni znanstveni rad
Podaci o odgovornosti
Čavlina, Nikola ; Feretić, Danilo ; Grgić, Davor ; Špalj, Srđan
engleski
Use of GOTHIC Code for Assessment of Equipment Environmental Qualification
Environmental qualification (EQ) of equipment important to safety in nuclear power plants ensures its capability to perform designated safety function on demand under postulated service conditions, including harsh accident environment (e.g. LOCA, HELB). The computer code GOTHIC was used to calculate pressure and temperature profiles inside NPP Krško containment during limiting LOCA and MSLB accidents. The results of the new best-estimate containment code are compared to the older CONTEMPT code using the same input data and assumptions. The predictions obtained by both codes are very similar. As a result of the calculation the envelopes of the LOCA and MSLB pressures and temperatures, as used in FSAR/USAR Chapter 6, can be used in EQ project.
environmental qualification; nuclear power plants; accident environment
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
227-235-x.
1996.
objavljeno
Podaci o matičnoj publikaciji
Nuclear Option in Countries with Small and Medium Electricity Grid
Knapp, Vladimir ; Čavlina, Nikola
Hrvatsko nuklearno društvo
Podaci o skupu
International Conference: Nuclear Option in Countries with Small and Medium Electricity Grid
predavanje
07.10.1996-09.10.1996
Opatija, Hrvatska