Influence of Different Shade-Matching Devices on Natural Teeth Color Assessment (CROSBI ID 640537)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Knezović Zlatarić, Dubravka ; Ćelić, Robert ; Žagar, Maja ; Pezo, Hrvoje Influence of Different Shade-Matching Devices on Natural Teeth Color Assessment // International dental journal. 2015. str. 82-82

Podaci o odgovornosti

Knezović Zlatarić, Dubravka ; Ćelić, Robert ; Žagar, Maja ; Pezo, Hrvoje

engleski

Influence of Different Shade-Matching Devices on Natural Teeth Color Assessment

Aim and purpose: Electronic shade-selection devices improve the accuracy and reliability of dental shade selection because they are not influenced by significant visual selection parameters, such as illumination and operator variability. The purpose of the study was to evaluate the inter-device repeatability in natural teeth color measurement using two different shade-matching devices. Materials and method: Under standardized clinical conditions two devices (VITA Easyshade Advance 4.0 and SpectroShade-Micro) were used to record the color of 30 right upper central incisors in 30 participants. One observer, well trained in colour assessment and handling of the dental shade-matching devices, determined teeth color. CIE L*a*b* values were determined and ΔE between the measurements was calculated. Results: Paired samples t-test revealed statistically significant difference in all determined CIE Lab values between two shade-matching devices (p < 0.05). VITA Easyshade Advance 4.0 assessed higher L* and lower a* and b* values in comparison to SpectroShade-Micro. The mean color difference (dE) for all L*a*b* measurements between two devices was 9.02 (SD 2.04). Inter-device repeatability in CIE L*a*b* measurements for both shadematching devices was low (ICCL value = 0.44 ; ICCa value = 0.11 ; ICCb value = 0.77). Summary and conclusions: The results of this study revealed low inter-device repeatability probably due to the differences in device measuring techniques (spot and surface measurement) and teeth irradiation angle as well as reflection light receivement angle. Therefore, it can be concluded that two shade- matching devices are not comparable and the measured values cannot be exchanged between the dentists and dental technicians in everyday dental clinical practice

shade-matching device ; natural teeth

Knjiga sažetaka objavljena u: International dental journal. 65 (2015), suppl. 2 ; pp. 1–196

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

82-82.

2015.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

International dental journal

0020-6539

Podaci o skupu

103rd FDI Annual World Dental Congress

poster

22.09.2015-25.09.2015

Bangkok, Tajland

Povezanost rada

Dentalna medicina