Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies (CROSBI ID 232068)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kasper, Manuel ; Traxler, Lukas ; Salopek, Jasmina ; Grabmayr, Herwig ; Ebner, Andreas ; Kienberger, Ferry Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies // Biosensors, 6 (2016), 2; 23, 13. doi: 10.3390/bios6020023

Podaci o odgovornosti

Kasper, Manuel ; Traxler, Lukas ; Salopek, Jasmina ; Grabmayr, Herwig ; Ebner, Andreas ; Kienberger, Ferry

engleski

Broadband 120 MHz Impedance Quartz Crystal Microbalance (QCM) with Calibrated Resistance and Quantitative Dissipation for Biosensing Measurements at Higher Harmonic Frequencies

We developed an impedance quartz crystal microbalance (QCM) approach with the ability to simultaneously record mass changes and calibrated energy dissipation with high sensitivity using an impedance analyzer. This impedance QCM measures frequency shifts and resistance changes of sensing quartz crystals very stable, accurately, and calibrated, thus yielding quantitative information on mass changes and dissipation. Resistance changes below 0.3 W were measured with corresponding dissipation values of 0.01 U (micro dissipation units). The broadband impedance capabilities allow measurements between 20 Hz and 120 MHz including higher harmonic modes of up to 11th order for a 10 MHz fundamental resonance frequency quartz crystal. We demonstrate the adsorbed mass, calibrated resistance, and quantitative dissipation measurements on two biological systems including the high affinity based avidin-biotin interaction and nano- assemblies of polyelectrolyte layers. The binding affinity of a protein-antibody interaction was determined. The impedance QCM is a versatile and simple method for accurate and calibrated resistance and dissipation measurements with broadband measurement capabilities for higher harmonics measurements.

quartz crystal microbalance ; impedance analysis ; biosensing ; dissipation ; higher harmonics

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (2)

2016.

23

13

objavljeno

2079-6374

10.3390/bios6020023

Povezanost rada

Biotehnologija, Fizika, Kemija

Poveznice
Indeksiranost