Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Measuring the influence of telescopic Galileo system on visual acuity of paediatric dentists in a simulated clinical environment (CROSBI ID 639467)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Negovetić Vranić, Dubravka ; Urlić, Iris ; Jeličić, Jesenka ; Bučević, Petra ; Čuković-Bagić, Ivana Measuring the influence of telescopic Galileo system on visual acuity of paediatric dentists in a simulated clinical environment // European archives of paediatric dentistry. 2016. str. 303-304 doi: 10.1007/s40368-016-0245-9

Podaci o odgovornosti

Negovetić Vranić, Dubravka ; Urlić, Iris ; Jeličić, Jesenka ; Bučević, Petra ; Čuković-Bagić, Ivana

engleski

Measuring the influence of telescopic Galileo system on visual acuity of paediatric dentists in a simulated clinical environment

Aim: The purpose of the study was to compare near visual acuity of dentists without optical aids (VSC) and with use of the Galilean telescope system (VGA2) with magnification of x 2.5 , distance of 350 mm in simulated clinical conditions. Methods: The study included 50 dentists (visual acuity 1.0 without correction). Miniaturized Snellen visual test was placed in the molar cavity of dental phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) without correction at a distance of 300-400 mm (VSC) ; 2) with Galilean loupes with magnification of x2.5, focal length 350mm. Results: The distribution of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. Results by Wilcoxon Signed Rank test indicated a statistically significant difference in the distribution of recorded visual acuity between VSC and VGA2 optical system (W = - 403.5 ; p <0.001). Conclusion: using VGA2, 5 system higher values of near visual acuity were recorded compared to near visual acuity without magnifying aids (VSC).

visual acuity ; miniturized Snellen optotype ; magnification systems ; Galilean optical systems ; dental loupes

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

303-304.

2016.

nije evidentirano

objavljeno

10.1007/s40368-016-0245-9

Podaci o matičnoj publikaciji

European archives of paediatric dentistry

1818-6300

1996-9805

Podaci o skupu

13th Congress of the European Academy of Paediatric Dentistry, 2016

predavanje

03.06.2016-05.06.2016

Beograd, Srbija

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost