Analysis of influence of panel size on PV panel operating temperature (CROSBI ID 639394)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Grubišić-Čabo, Filip ; Marinić-Kragić, Ivo ; Nižetić, Sandro ; Papadopoulos, Agis
engleski
Analysis of influence of panel size on PV panel operating temperature
This paper deals with influence of PV panel size on its average working temperature. A numerical model has been established in accordance with experimental results gained in realistic operating conditions. Established model was used to gain information of size influence on average panel temperature. Results show significant difference in average temperature between several distinct panel sizes. Since the dependence between temperature and electrical efficiency of PV panel is already known, provided information can be used in future design of PV systems.
photovoltaic; cooling; temperature; efficiency; numerical; panel design
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
2016.
objavljeno
Podaci o matičnoj publikaciji
2016 International Multidisciplinary Conference On Computer And Energy Science (SpliTech)
Milanović, Željka ; Perković, Toni ; Nižetić, Sandro ; Šolić, Petar ; Patrono, Luigi
Split: Fakultet elektrotehnike, strojarstva i brodogradnje Sveučilišta u Splitu
978-953-290-063-7
Podaci o skupu
2016 International Multidisciplinary Conference On Computer And Energy Science (SpliTech)
predavanje
13.07.2016-15.07.2016
Split, Hrvatska