Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 831218

Risk analysis of the preanalytical process based on quality indicators data


Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea; Kardum Paro, Mirjana Mariana; Prkačin, Ingrid; Devčić-Jeras, Ana
Risk analysis of the preanalytical process based on quality indicators data // Clinical chemistry and laboratory medicine (2017) (znanstveni, prihvaćen)


CROSBI ID: 831218 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Risk analysis of the preanalytical process based on quality indicators data

Autori
Flegar-Meštrić, Zlata ; Perkov, Sonja ; Radeljak, Andrea ; Kardum Paro, Mirjana Mariana ; Prkačin, Ingrid ; Devčić-Jeras, Ana

Vrsta, podvrsta
Radovi u časopisima, znanstveni

Izvornik
Clinical chemistry and laboratory medicine (2017)

Status rada
Prihvaćen

Ključne riječi
failure mode and effects analysis (FMEA) ; harmonization ; preanalytical process ; quality indicators ; risk analysis

Sažetak
Background: Improving quality and patient safety in the medical biochemistry laboratory accredited according to the International Standard Organization (ISO 15189:2012) requires the patient-centered evaluation of errors based on the implementation of quality indicators (QIs) across the total testing process. Our main goal was to achieve quality improvement of the preanalytical process in an emergency laboratory which had the highest error rate using risk management principles. Methods: Failure mode and effects analysis (FMEA) was applied to analyze predefined preanalytical QIs and score laboratory failures for the failure demerit value (FDV), probability of failure (PF) and probability of failure remedy (PFR). Based on obtained scores (on a 10-point scale) risk priority numbers (RPNs) were calculated. Results: A total of five failure modes were identified in the preanalytic process. The calculated risks were “sample hemolysis” (RPN, 168), “misidentified samples” (RPN, 108), “samples clotted” (RPN, 90), “sample volume error” (RPN, 72) and “samples transported at inappropriate temperature” (RPN, 24). The activation of corrective risk-reducing measures for failure modes with RPN ≥ 30 resulted in quality improvement with the significant decrease in reevaluated RPNs.

Izvorni jezik
Engleski

Znanstvena područja
Kliničke medicinske znanosti

Napomena
Ahead of print



POVEZANOST RADA


Ustanove:
Klinička bolnica "Merkur",
Nastavni zavod za javno zdravstvo "Dr. Andrija Štampar"


Citiraj ovu publikaciju

Flegar-Meštrić, Zlata; Perkov, Sonja; Radeljak, Andrea; Kardum Paro, Mirjana Mariana; Prkačin, Ingrid; Devčić-Jeras, Ana
Risk analysis of the preanalytical process based on quality indicators data // Clinical chemistry and laboratory medicine (2017) (znanstveni, prihvaćen)
Flegar-Meštrić, Z., Perkov, S., Radeljak, A., Kardum Paro, M., Prkačin, I. & Devčić-Jeras, A. (2017) Risk analysis of the preanalytical process based on quality indicators data. Prihvaćen za objavljivanje u Clinical chemistry and laboratory medicine. [Preprint].
@unknown{unknown, year = {2017}, keywords = {failure mode and effects analysis (FMEA), harmonization, preanalytical process, quality indicators, risk analysis}, journal = {Clinical chemistry and laboratory medicine}, title = {Risk analysis of the preanalytical process based on quality indicators data}, keyword = {failure mode and effects analysis (FMEA), harmonization, preanalytical process, quality indicators, risk analysis} }
@unknown{unknown, year = {2017}, keywords = {failure mode and effects analysis (FMEA), harmonization, preanalytical process, quality indicators, risk analysis}, journal = {Clinical chemistry and laboratory medicine}, title = {Risk analysis of the preanalytical process based on quality indicators data}, keyword = {failure mode and effects analysis (FMEA), harmonization, preanalytical process, quality indicators, risk analysis} }

Časopis indeksira:


  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
  • Scopus
  • MEDLINE





Contrast
Increase Font
Decrease Font
Dyslexic Font