Timpanična, frontalna i aksilarna temperatura u djece (CROSBI ID 229948)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Antabak, Anko ; Šiško, Jerko ; Romić, Ivan ; Papeš, Dino ; Pasini, Miram ; Halužan, Damir ; Bogović, Marko ; Sršen Medančić, Suzana ; Ćavar, Stanko ; Luetić, Tomislav et al. Timpanična, frontalna i aksilarna temperatura u djece // Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora, 138 (2016), 1-2; 30-33

Podaci o odgovornosti

Antabak, Anko ; Šiško, Jerko ; Romić, Ivan ; Papeš, Dino ; Pasini, Miram ; Halužan, Damir ; Bogović, Marko ; Sršen Medančić, Suzana ; Ćavar, Stanko ; Luetić, Tomislav ; Fuchs, Nino ; Andabak, Matej ; Prlić, Ivica ; Ćurković, Selena

hrvatski

Timpanična, frontalna i aksilarna temperatura u djece

Summary.The purpose of this study was to compare the results or body temperature measurements obtained by standard axillary thermometers with the results of infrared tympanic and frontal ski n thermometry in afebrile children. This study comprises a single- center, prospective comparison trial. A total or' 345 afebrile children aged 4 to 16 years hospitalized in the pediatric surgery department for elective surgery were included. One thousand axillary, tympanic and frontal measure­ ments were obtained and compared. We used two different infrurcd thermometers in this study ; one type measured the tympanic temperature, the other the temperature on the forehead. The axillary temperature measured with the glass ther­ mometer was set as the standard. Each patient was exposed to a constant environmental temperature for a minimum of I0 min before simultaneous temperature measurements. The mean frontal temperature 36.9± 0.38 °C was equal to the axillary temperature 36.9± 0.16 °C. The mean tympanic temperature wns 36.3 ± 0.98 °C. The mean difference between the tym­ panic and axillary temperatures was -0.4 °C. The tympanic temperature had a threefold greater dispersion than fr-ontal and a fivefold greater dispersion than axillary temperature. The results or this study suggest that the axillary temperature mea­ sured with glass thermometer has the least dispersion. Somewhat less reliable is the frontal temperature-measured with infrared thermometer. The least reliable is tympanic temperatun: measurement

Tjelesna temperatum - fiziologijn ; Termografija instrumentarij ; mctode ; Termomctri- standardi ; Infracrve- ne zrakc ; Tempcmturu kozc - fiziologija ; Buhnjic fiziologija ; Aksila - fiziologija ; Prospektivne studije

Rad je rezultat zajedničkih istraživanja istraživača Jedinice za dozimetriju zračenja Instituta za medicinska istraživanja i medicinu rada i klinike za dječju kirurgiju KBC zagreb temeljem interno financiranog istraživačkog projekta

engleski

Frontal, Axillary and Tympanic Temperature measurements on children

nije evidentirano

Body temperature - physiology ; Thermography · instmmentation ; methods ; Thermometry - standards ; Infrared rays ; Axilla - physiology ; Skin temperature - physiology ; Tympanic membrane - physiology ; Prospective studies