Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS (CROSBI ID 637163)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Katić, Višnja ; Blagović, Branka ; Ciganj, Zlatko ; Pavlić, Andrej ; Špalj, Stjepan CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS // European Journal of Orthodontics / David Rice (ur.). Oxford University Press, 2016. str. e121-e121

Podaci o odgovornosti

Katić, Višnja ; Blagović, Branka ; Ciganj, Zlatko ; Pavlić, Andrej ; Špalj, Stjepan

engleski

CORRELATION BETWEEN ION RELEASE, WIRE TYPE AND ACIDITY VALUES OF ARTIFICIAL SALIVA OF NICKEL- TITANIUM WIRES WITH DIFFERENT COATINGS

AIM: To explore correlation between ion release, wire type and acidity values of artificial saliva of nickel-titanium wires with different coatings. MATERIALS AND METHOD: Uncoated (NiTi) and rhodium-coated (RhNiTi) nickel-titanium wires were immersed in artificial saliva solutions (1.5 g/l KCl, 1.5 g/l NaHCO3, 0.5 g/l, NaH2PO4–H2O, 0.5 g/l KSCN, 0.9 g/l lactic acid). The pH values were adjusted to 5.5 and 6.6 with the use of lactic acid and NaOH. Specimens were incubated at 37 °C for 28 days. Released nickel and titanium ions were measured by means of inductively coupled plasma-optical emission spectroscopy (ICP-OES). All experiments were performed in triplicate. Data was analysed with two-way ANOVA and Student-Newman-Keuls post-hoc test. RESULTS: The release of nickel correlated to the wire type (p=0, 025 ; η2=0, 263), but not to the pH value. The NiTi wire released significantly less nickel at pH value 6.6 (p=0, 018 ; η2=0, 698). The release of titanium correlated to the wire type (p<0, 001 ; η2=0, 801) and the pH value (p<0, 001 ; η2=0, 633). The RhNiTi wire released significantly less titanium at pH value 6.6 (p=0, 004 ; η2=0, 798). CONCLUSIONS: Coating on the wire surface modifies the release of ions from nickel-titanium wires in artificial saliva with different acidity. The release of titanium depends on acidity level of artificial saliva.

artificial saliva; orthodontic archwires; ion release

Izrađeno i financirano u sklopu projekta “Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata” Hrvatske zaklade za znanost (IP-2014-09-7500) voditelja Stjepana Špalja

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

e121-e121.

2016.

objavljeno

Podaci o matičnoj publikaciji

European Journal of Orthodontics

David Rice

Oxford University Press

Podaci o skupu

92nd Congress of the European Orthodontic Society

poster

11.06.2016-16.06.2016

Stockholm, Švedska

Povezanost rada

Kemijsko inženjerstvo, Dentalna medicina