The LET effect on the response of the chlorobenzene-ethanol-trimethylpentane dosimetry system. (CROSBI ID 483577)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa

Miljanić, Saveta ; Ražem, Dušan The LET effect on the response of the chlorobenzene-ethanol-trimethylpentane dosimetry system. // Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health / Obelić, B.; Ranogajec-Komor, M.; Miljanić, S. et al. (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2002. str. 7p-02-x

Podaci o odgovornosti

Miljanić, Saveta ; Ražem, Dušan

engleski

The LET effect on the response of the chlorobenzene-ethanol-trimethylpentane dosimetry system.

The chlorobenzene-ethanol-trimethylpentane (CET) chemical dosimetry system is currently used for dosimetry calibration work and as a basis for the accident and emergency personal dosimeter DL-M4. In the present work the results of determination of the radiation-chemical yield, G(HCl), for the CET system, as well as the response of DL-M4 in different neutron fields ranging from 0.35 to 19.3 MeV mean energy neutrons, are summarised. The relation of G(HCl) for the CET system to LET of incident heavy charged particles is also evaluated on the basis of the previously published data. It was found that the radiation-chemical yield, G(HCl), is nearly constant in neutron energy range from about 1.7 MeV to 14.5 MeV and equal to 0.39±0.02 mmol J-1 (or 78% of the value for 60Co gamma rays). Following this, the response to neutron tissue dose in the same energy range, relative to the same tissue dose of gamma radiation is nearly unity since the CET system contains 14.0% hydrogen, i.e. 4% more than ICRU muscle tissue. For neutrons of 19.3 MeV mean energy, the G value is 12% lower and equals to 0.35 mmol J-1. From the measured dependence of the G value upon LET of heavy charged particles and data about the LET distribution for monoenergetic neutrons, the response of the CET system to monoenergetic neutrons was calculated. A very good agreement between this calculation and the experimental results for neutrons was obtained. These results enable predictions of the response to be made in radiation fields with the known LET distributions.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

7p-02-x.

2002.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of IRPA Regional Congress on Radiation Protection in Central Europe - Radiation Protection and Health

Obelić, B.; Ranogajec-Komor, M.; Miljanić, S.; Krajcar Bronić, I

Zagreb: Hrvatsko društvo za zaštitu od zračenja

Podaci o skupu

Nepoznat skup

poster

29.02.1904-29.02.2096

Povezanost rada

Kemija