Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism (CROSBI ID 229359)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Biščević, Alma ; Bohac, Maja ; Končarević, Mateja ; Antičić, Marija ; Dekaris, Iva ; Patel, Sudi Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism // Graefe's archive for clinical and experimental ophthalmology, 253 (2015), 12; 2325-2333. doi: 10.1007/s00417-015-3177-x

Podaci o odgovornosti

Biščević, Alma ; Bohac, Maja ; Končarević, Mateja ; Antičić, Marija ; Dekaris, Iva ; Patel, Sudi

engleski

Vector analysis of astigmatism before and after LASIK: a comparison of two different platforms for treatment of high astigmatism

PURPOSE: To compare the outcomes of astigmatic laser in- situ keratomileusis (LASIK) procedures between two different platforms using J0 and J45 vector analysis. METHODS: Patients were divided into four groups, depending on the type of astigmatism and laser platform on which they were treated. Astigmatism was between 2 and 7 diopters (D). One hundred and thirty-five patients with myopic astigmatism (246 eyes) and 102 patients with mixed astigmatism (172 eyes) underwent unremarkable LASIK correction on Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S laser platform. The preoperative and postoperative sphere, negative cylinder [C] and axis (ø) of manifest refractions were subjected to vector analysis by calculations of the standard J0 (cos [4π(ø-90)/360]xC/2) and J45 (sin[4π(ø-90)/360]xC/2). RESULTS: Reporting the key results, we found J0 significantly reduced after LASIK in both groups (p < 0.001) but not J45. There was no significant association between individual pairs of pre and postoperative J0 & J45 values. There was no significant difference between the outcomes of the two platforms. CONCLUSIONS: Wavelight Allegretto 400Hz and Schwind Amaris 750S showed excellent results for treating patients with astigmatism, regardless whether it is mixed or myopic astigmatism. The J45 did not reduce significantly possibly because of the low number of eyes with oblique astigmatism. There was no genuine difference post-operatively between groups treated on two different laser platforms according to the vector analyses.

Astigmatism ; Excimer laser ; LASIK ; Vector analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

253 (12)

2015.

2325-2333

objavljeno

0721-832X

10.1007/s00417-015-3177-x

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost