Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Uncertainties in façade fire tests – measurements and modeling (CROSBI ID 635374)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Anderson, Johan ; Boström, Lars ; Jansson McNamee, Robert ; Milovanović, Bojan Uncertainties in façade fire tests – measurements and modeling // 2nd International conference Fire Safety of Facades - FSF2016 / Vallerent, Stephanie (ur.). Lund: MATEC Web of Conferences, 2016. str. 1-13

Podaci o odgovornosti

Anderson, Johan ; Boström, Lars ; Jansson McNamee, Robert ; Milovanović, Bojan

engleski

Uncertainties in façade fire tests – measurements and modeling

In this paper a comparison between test and modelling results are performed for two large-scale façade fire testing methods, namely SP Fire 105 and BS 8414-1. In order to be able to compare tests and modelling the uncertainties have to be quantified both in the test and the modelling. Here we present a methodology based on deterministic sampling to quantify uncertainties in the modelling input. We find, in general good agreement between the models and the test results. Moreover, temperatures estimated by plate thermometers is indicated to be less sensitive to small variations in model input and is thus suitable for these kind of comparisons.

facade fire test; uncertainties; modelling; measurements

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-13.

2016.

objavljeno

Podaci o matičnoj publikaciji

Vallerent, Stephanie

Lund: MATEC Web of Conferences

978-2-7598-2018-4

Podaci o skupu

2nd International conference Fire Safety of Facades

predavanje

11.05.2016-13.05.2016

Lund, Švedska

Povezanost rada

Građevinarstvo