Computed tomography: Influence of part position on measurement results (CROSBI ID 635316)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Horvatić, Amalija ; Runje, Biserka ; Novak, Igor Computed tomography: Influence of part position on measurement results // Dimensional X-ray Computed Tomography Conference 2016. Teddington: National Physical Laboratory, 2016. str. 11-11

Podaci o odgovornosti

Horvatić, Amalija ; Runje, Biserka ; Novak, Igor

engleski

Computed tomography: Influence of part position on measurement results

Computed tomography (CT) is a relatively new method in the field of dimensional measurement. It is a non destructive, non tactile coordinate method for dimensional measurements. Its advantage compared to other coordinate measurement methods is that it provides insight into internal geometry of measured parts without destroying them. However, due to large number of influential factors, measurement uncertainty is not yet defined and measurement traceability is still not achieved. One of the approaches to achieve traceability is to identify and determine all influential factors as well as their impact on measurements. In this paper, one of the uncertainty components - the position of the measured part - was observed. Standard uncertainty was calculated based on observations obtained under repeatability and reproducibility conditions. Measurements were conducted in three different object orientations and repeated four times. In accordance with the document JCGM 100 201x cd (revised Guide to the expression of uncertainty in measurement) from the year 2015 the Bayesian approach was used to evaluate the type A standard uncertainty component. The test sample was an aluminium cylinder specially shaped and manufactured so that, apart from the dimensional characteristic (length), two geometrical characteristics (flatness and parallelism) were investigated. Scanning was conducted on Nikon XTH 225, while the measurements of the scanned model were done in the software Volume Graphics StudioMAX 2.2. Finally, the results were compared with those obtained using the tactile coordinate measurement machine. 

Computed tomography; Influence parameters; Part position; Measurement results

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

11-11.

2016.

objavljeno

Podaci o matičnoj publikaciji

Dimensional X-ray Computed Tomography Conference 2016

Teddington: National Physical Laboratory

Podaci o skupu

Dimensional X-ray Computed Tomography Conference 2016

poster

10.05.2016-10.05.2016

Teddington, Ujedinjeno Kraljevstvo

Povezanost rada

Strojarstvo