Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

New "L value" parameter simplifies and enhances hip ultrasound interpretation in the detection of developmental dysplasia of the hip (CROSBI ID 228156)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Rakovac, Ivan ; Tudor, Anton ; Šestan, Branko ; Prpić, Tomislav ; Gulan, Gordan ; Mađarević, Tomislav ; Šantić, Veljko ; Ružić, Lana New "L value" parameter simplifies and enhances hip ultrasound interpretation in the detection of developmental dysplasia of the hip // International orthopaedics, 35 (2011), 10; 1523-1528. doi: 10.1007/s00264-011-1256-0

Podaci o odgovornosti

Rakovac, Ivan ; Tudor, Anton ; Šestan, Branko ; Prpić, Tomislav ; Gulan, Gordan ; Mađarević, Tomislav ; Šantić, Veljko ; Ružić, Lana

engleski

New "L value" parameter simplifies and enhances hip ultrasound interpretation in the detection of developmental dysplasia of the hip

Abstract PURPOSE: The purpose of this study was to simplify and enhance the ultrasound (US) analysis of the infant's hip by introducing a novel parameter named "L value" into the widely used Graf method. METHODS: We analysed 508 ultrasonographic images of the hips in infants aged three months. The images were first evaluated using the Graf measurements. On the same images, two additional measurements were performed in order to define the new parameter that was named L value. The threshold values of the new L value were identified based on the highest specificity as well as sensitivity for discrimination between the Graf groups. Those values were then used in order to reclassify the hips into three simplified groups. Inter- observer agreement was estimated by Cohen's kappa coefficient. RESULTS: The threshold values for the L value between Graf groups Ia and Ib was 0.46, between Ib and IIb was 0.68 and between IIb and IIc was 0.92. Correlation analysis between Graf's classification and the values of the L value was performed and was proved to be statistically significant, r = 0.49 ; p < 0.001. After simplifying the classification into three newly defined groups of patients depending on the degree of hip development, the correlation coefficient was much higher, r = 0.94, r (2) = 0.88 for p < 0.001. Inter-observer agreement for the L value was substantial. CONCLUSIONS: The new L value parameter in Graf's ultrasound hip evaluation enables a faster, simpler, more reliable and more unbiased classification for developmental dysplasia of the hip as the L value changes proportionally with the hip maturity.

ultrasound ; hip ; Graf method

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

35 (10)

2011.

1523-1528

objavljeno

0341-2695

10.1007/s00264-011-1256-0

Povezanost rada

Javno zdravstvo i zdravstvena zaštita, Kineziologija, Kliničke medicinske znanosti

Poveznice
Indeksiranost