EVALUATION OF MEASUREMENT UNCERTAINTY IN ELECTROCHEMICAL TEST METHODS (CROSBI ID 634179)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Lokas, Lea ; Runje, Biserka ; Alar, Vesna
engleski
EVALUATION OF MEASUREMENT UNCERTAINTY IN ELECTROCHEMICAL TEST METHODS
In this work, electrochemical measurements on aluminium alloy 6060 were conducted in distilled water in order to estimate the mathematical model and to evaluate uncertainty of measurement. Potentiodynamic polarization and Tafel fit were employed four times under the same pre-treatment procedure and the same experimental conditions. Results have shown deviation in collected parameters but rates of measurement uncertainty and expanded measurement uncertainty are acceptable for application in which aluminium alloy 6060 is commonly used.
electrochemical measurement; measurement uncertainty; aluminium alloy
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
166-173.
2016.
objavljeno
Podaci o matičnoj publikaciji
KORMAT 2016
Stojanović, Ivan ; Alar, Vesna ; Šimunović, Vinko
Zagreb: Hrvatsko društvo za zaštitu materijala (HDZaMa)
Podaci o skupu
22. Međunarodno savjetovanje o zaštiti materijala i industrijskom finišu
predavanje
20.04.2016-20.04.2016
Zagreb, Hrvatska