PREDICTIVE STRUCTURE FOR CURRENT REFERENCE GENERATION OF ACTIVE POWER FILTER (CROSBI ID 632388)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Kilić, Tomislav ; Milun, Stanko
engleski
PREDICTIVE STRUCTURE FOR CURRENT REFERENCE GENERATION OF ACTIVE POWER FILTER
The shunt active power filters are used to atenuate the harmonic currents in power systems by injecting equal but opposite compensating currents. Successful control of the active filters requires an accurate current reference. In this paper the current reference determination based on predictive filtering structure is presented. Current reference is obtained by taking the difference of load current and its fundamental harmonic. For fundamental harmonic determination with no time delay a combination of digital predictive filter and low pass filter is used.
active filter; harmonics; predictive filter
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
2002.
objavljeno
Podaci o matičnoj publikaciji
12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation
Zagreb:
Podaci o skupu
12th IMEKO TC4 International Symposium Electrical Measurements and Instrumentation
predavanje
25.09.2002-27.09.2002
Zagreb, Hrvatska