Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

The impact of daily set-up variation on head and neck advance 3D conformal radiation therapy (ConPas) (CROSBI ID 631236)

Neobjavljeno sudjelovanje sa skupa | neobjavljeni prilog sa skupa | međunarodna recenzija

Radojčić, Milan ; Smilović Radojčić, Đeni ; Mijolović, Nina ; Begović, Nives ; Gašparović, Miran The impact of daily set-up variation on head and neck advance 3D conformal radiation therapy (ConPas) // South east Europe technology in radiation technology Zagreb, Hrvatska, 06.11.2015-08.11.2015

Podaci o odgovornosti

Radojčić, Milan ; Smilović Radojčić, Đeni ; Mijolović, Nina ; Begović, Nives ; Gašparović, Miran

engleski

The impact of daily set-up variation on head and neck advance 3D conformal radiation therapy (ConPas)

Accuracy and reproducibility of the patient’s position are fundamental to the successful delivery of radiation therapy. The purpose of this study was to analyze the magnitude of setup errors and the impact of those corrections on the delivered dose to the tumor and organs at risk (OARs). A series of 30 patients with H&N cancer were enrolled in a trial to examine daily radiation set-up accuracy. These patient where treated with field design using an advanced 3D planning techniques (ConPas). Immobilisation and alignment were performed using thermoplastic masking, base plate fixation, three point laser alignment and portal imaging evaluation per protocol. Positional errors were applied in initial plans and trough DVH, dose to the tumor and normal nearby healthy structures were analyzed. For all patient mean set-up errors were 0.23 cm, 0.28 cm, 0.19 cm in three directions (lat., long., vert.). The standard deviations for systematic setup corrections in lat., long, and vert. directions were 0.24 cm, 0.10 cm, 0.27 cm respectively. The quality of dose coverage for the PTV degraded slightly and dose to OARs change significantly (maximal change: medulla 8.29 %, Parotid L 8, 4 %, Parotid D 14, 7 %). The accuracy of patient positioning will improve the success of radiation treatment. The use of specific clinical protocols for patients' setup can effectively detect setup errors and this will reduce radiation dose to critical organs.

radiotherapy; set-up variations; head and neck cancer

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

nije evidentirano

nije evidentirano

Podaci o skupu

South east Europe technology in radiation technology

predavanje

06.11.2015-08.11.2015

Zagreb, Hrvatska

Povezanost rada

Fizika, Temeljne medicinske znanosti