Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Effect of transformer symmetry on intrabody communication channel measurements using grounded instruments (CROSBI ID 223354)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Lučev Vasić, Željka ; Krois, Igor ; Cifrek, Mario Effect of transformer symmetry on intrabody communication channel measurements using grounded instruments // Automatika : časopis za automatiku, mjerenje, elektroniku, računarstvo i komunikacije, 1 (2016), 1-12. doi: 10.7305/automatika.2016.01.1583

Podaci o odgovornosti

Lučev Vasić, Željka ; Krois, Igor ; Cifrek, Mario

engleski

Effect of transformer symmetry on intrabody communication channel measurements using grounded instruments

Transformers with one winding terminal symmetrical with respect to ground (capacitances between their terminals and ground are the same) are referred to as balun transformers, and are often used for decoupling in the measurements of the intrabody communication (IBC) system transmission characteristics. We measured IBC system amplitude and phase transmission characteristics using three types of galvanic decouplers: non-symmetric RF transformers, balun transformers with center tap grounded and balun transformers with center tap floating. Four possible electrode configurations (AA, AB, BA, and BB) and four electrode arrangements (GSGS, GSSG, SGGS, and SGSG), result in a total of 16 measurement scenarios for each of three measurement setups. We showed that the change in the measured amplitude for different signal and ground electrode arrangements while measuring with non-symmetric transformers is influenced by the transformer symmetry to the ground, and not the capacitive intrabody communication transmission characteristics. The change of the amplitude in case symmetric balun transformers are used is negligible for practical purposes.

Capacitive coupling; Electrode configuration and arrangement; Intrabody communication (IBC); Transformer symmetry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

1

2016.

1-12

objavljeno

0005-1144

10.7305/automatika.2016.01.1583

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost