Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Spectroscopic Study Of The Laser Produced Dysprosium Plasmas (CROSBI ID 77163)

Prilog u časopisu | izvorni znanstveni rad

Veža, Damir ; Milošević, Slobodan Spectroscopic Study Of The Laser Produced Dysprosium Plasmas // Fizika A, 6 (1997), 1; 1-13-x

Podaci o odgovornosti

Veža, Damir ; Milošević, Slobodan

engleski

Spectroscopic Study Of The Laser Produced Dysprosium Plasmas

We report the observations of the excimer laser-induced dysprosium plasma. The time evolution of DyI and DyII selected resonance line intensities and line widths was studied. It is found that the time development of the plasma plume can be significantly influenced by the presence of argon backing gas. The comparison of the measurements of dysprosium atomic line widths made in vacuum and in argon shows a small influence of argon on the measured Stark line widths.

laser ablation; dysprosium

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

6 (1)

1997.

1-13-x

objavljeno

1330-0008

Povezanost rada

Fizika