Effects of mandibular advancement device treatment on arterial stiffness and glucose metabolism in patients with mild to moderate obstructive sleep apnea: a prospective 1 year study. (CROSBI ID 222740)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Galić, Tea ; Božić, Joško ; Ivković, Natalija ; Gunjača, Grgo ; Kurir Tičinović, Tina ; Đogaš, Zoran Effects of mandibular advancement device treatment on arterial stiffness and glucose metabolism in patients with mild to moderate obstructive sleep apnea: a prospective 1 year study. // Sleep and breathing, 20 (2016), 1; 69-77. doi: 10.1007/s11325-015-1186-y

Podaci o odgovornosti

Galić, Tea ; Božić, Joško ; Ivković, Natalija ; Gunjača, Grgo ; Kurir Tičinović, Tina ; Đogaš, Zoran

engleski

Effects of mandibular advancement device treatment on arterial stiffness and glucose metabolism in patients with mild to moderate obstructive sleep apnea: a prospective 1 year study.

STUDY OBJECTIVES: An independent association between obstructive sleep apnea (OSA) and cardiovascular events has been reported, suggesting that OSA may lead to cardiometabolic dysregulation. We prospectively investigated the effect of mandibular advancement device (MAD) treatment on arterial stiffness, glucose metabolism, and certain inflammatory markers as predictors of cardiometabolic risk in mild to moderate OSA patients. METHODS: A total of 18 patients with mild to moderate OSA were prospectively enrolled in the study to determine the effects of MAD treatment at 3 months and 1 year following initiation of the treatment. Sleep studies, arterial stiffness assessment, and laboratory analyses were obtained at the baseline and at the time of follow-up. The data collected at 1 year were compared to baseline values. RESULTS: There was a significant decrease in apnea-hypopnea index (AHI) after 1 year of treatment when compared to baseline (22.9 ± 5.9 to 9.7 ± 4.5, P < 0.001). Furthermore, MAD treatment was associated with reduced levels of fasting plasma glucose values after 1 year of treatment (5.3 ± 0.5 to 4.9 ± 0.5 mmol/L, P < 0.001), as well as fasting plasma insulin values (14.1 ± 7.8 to 10.9 ± 6.4 μU/mL, P < 0.05) and HOMA-IR (3.3 ± 1.8 to 2.4 ± 1.4, P < 0.001). There was significant improvement in pulse wave velocity (9.3 ± 1.9 m/s at baseline to 8.1 ± 1.7 m/s, P < 0.05) after 1 year of treatment. Plasma level of an inflammatory marker fibrinogen decreased significantly from 3.4 ± 0.7 at baseline to 3.0 ± 0.9, (P < 0.05) at 1-year follow-up. CONCLUSIONS: The MAD treatment improved arterial stiffness, glucose metabolism, and insulin resistance in mild to moderate OSA patients after 1 year of treatment.

Obstructive sleep apnea ; Mandibular advancement device ; Arterial stiffness ; Cardiovascular risk ; Glucose metabolism