Minimum heat transfer area for Total Site heat recovery (CROSBI ID 222023)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Boldyryev, Stanislav ; Varbanov, Petar, Sabev ; Nemet, Andreja ; Klemeš, Jiří, Jaromír ; Kapustenko, Petro
engleski
Minimum heat transfer area for Total Site heat recovery
In this paper a further development of methodology for decreasing the capital cost for Total Site heat recovery by use of different utility levels is proposed. The capital cost of heat recovery system is estimated for certain temperature level of intermediate utility applying Total Site Profiles. Heat transfer area is reduced by selection of appropriate temperature of intermediate utility. Minimum of heat transfer area depends on slopes of Total Site Profiles in each enthalpy interval. This approach allows estimating the minimum of heat transfer area for heat recovery on Total Site level. Case study is performed for fixed film heat transfer coefficients of process streams and intermediate utilities. It indicates that the total heat transfer area of heat recovery can be different up to 49.15% for different utility temperatures.
Total Site heat recovery ; Heat transfer area ; Intermediate utility
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
87
2014.
1093-1097
objavljeno
0196-8904
10.1016/j.enconman.2014.04.029
Povezanost rada
Kemijsko inženjerstvo, Strojarstvo