Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

3D CONFORMAL RADIATION THERAPY (3D - CRT) VERSUS INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR ANAL CARCINOMA CASE AT UHC - ZAGREB (CROSBI ID 626359)

Prilog sa skupa u zborniku | ostalo | domaća recenzija

Barišić, Lovro ; Grego, Timor ; Bibić, Juraj ; Buinac, Ana ; Murković, Miljenko ; Kovačević, Nenad ; Babić, Julijan ; Hršak, Hrvoje 3D CONFORMAL RADIATION THERAPY (3D - CRT) VERSUS INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR ANAL CARCINOMA CASE AT UHC - ZAGREB // 10.Simpozij Hrvatskog društva za zaštitu od zračenja / Petrinec, Branko ; Bituh, Tomislav ; Mirta, Milić et al. (ur.). Zagreb: Hrvatsko društvo za zaštitu od zračenja, 2015. str. 101-105

Podaci o odgovornosti

Barišić, Lovro ; Grego, Timor ; Bibić, Juraj ; Buinac, Ana ; Murković, Miljenko ; Kovačević, Nenad ; Babić, Julijan ; Hršak, Hrvoje

engleski

3D CONFORMAL RADIATION THERAPY (3D - CRT) VERSUS INTENSITY MODULATED RADIATION THERAPY (IMRT) FOR ANAL CARCINOMA CASE AT UHC - ZAGREB

Anal carcinomas are relatively rare. The shape of planning target volume (PTV) presents challenge for 3D - CRT due to its horseshoe shape. In this work 3D - CRT planning technique was presented and compared with IMRT technique for anal carcinoma case. 3D - CRT plan was made with 7 field technique with 18 MV beams. IMRT plan was made with 7 field setup and with 6 MV beams. IMRT was planned with step and shoot IMRT method. Dosimetric evaluations were performed for both plans. Dose Volume Histogram (DVH) comparison showed similar PTV coverage and organs at risk (OAR) sparing for both plans. IMRT plan had higher conformality, but also had higher maximum dose. Dosimetric evaluations were in tolerances for both plans. Although IMRT showed slightly better OAR sparing and conformality, total patient dose for IMRT was higher than for 3D - CRT, so patient was irradiated with 3D - CRT technique.

Anal carcinoma; 3D conformal radiation therapy; Intensity modulated radiation therapy; Simultaneous Integrated Boost

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

101-105.

2015.

objavljeno

Podaci o matičnoj publikaciji

10.Simpozij Hrvatskog društva za zaštitu od zračenja

Petrinec, Branko ; Bituh, Tomislav ; Mirta, Milić ; Kopjar, Nevenka

Zagreb: Hrvatsko društvo za zaštitu od zračenja

1849-5060

Podaci o skupu

10. simpozij HRVATSKOG DRUŠTVA ZA ZAŠTITU OD ZRAČENJA

predavanje

15.04.2015-17.04.2015

Šibenik, Hrvatska

Povezanost rada

Fizika, Kliničke medicinske znanosti