LOCAL BACKGROUND NATURAL IONISING RADIATION - A REFERENCE LOCATION AT THE RESEARCH POLYGON OF THE INSTITUTE FOR MEDICAL RESEARCH AND OCCUPATIONAL HEALTH, ZAGREB (CROSBI ID 626291)
Prilog sa skupa u zborniku | izvorni znanstveni rad | domaća recenzija
Podaci o odgovornosti
Prlić, Ivica ; Surić Mihić, Marija ; Hajdinjak, Mladen ; Cerovac, Zdravko ; Bituh, Tomislav ; Tončić, Josip
engleski
LOCAL BACKGROUND NATURAL IONISING RADIATION - A REFERENCE LOCATION AT THE RESEARCH POLYGON OF THE INSTITUTE FOR MEDICAL RESEARCH AND OCCUPATIONAL HEALTH, ZAGREB
Validated and reliable measurement data are the foundation of any scientific report, especially in research fields that describe environmental stressors. In order to yield a trustworthy interpretation of environmental “events” monitored and explored by measuring ionising radiation, it is necessary to obtain accurate data on the local background radiation in the environment where research is conducted. Values of the measured ambient dose rate equivalent H*(10), an operational quantity for environmental monitoring used to characterise local natural background radiation, greatly depend on the geographic placement, geological composition, and urbanisation of the very location of the measurement. IMROH has designed and installed a measuring station within the research polygon “Šumbar” with the aim to establish it as a reference measuring station for local background ionising radiation for all future research regarding ionising radiation and its naturally, as well as accidentally, caused oscillations in the environment. Discrepancy in the H*(10) values between the two measuring locations is fully justified considering the fact that the Institute is located in an urban surrounding burdened by nearly every possible pollutant as well as buildings and is characterised by a specific city microclimate, while “Šumbar” is an ecologically untouched area, hunting grounds, and natural habitat mainly unaffected by modern life. Furthermore, knowing the H*(10) values at a remote and “unpolluted” location in real time (interactive communication with the measuring station) also enables a significantly faster regulatory reaction in cases of potential radiological accidents.
ionizing radiation; background radiation
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
347-352.
2015.
objavljeno
Podaci o matičnoj publikaciji
Zbornik radova 10. simpozija HRVATSKOG DRUŠTVA ZA ZAŠTITU OD ZRAČENJA
Petrinec, Branko ; Bituh, Tomislav ; Milić, Mirta ; Kopjar, Nevenka
Zagreb: Hrvatsko društvo za zaštitu od zračenja
1849-5060
Podaci o skupu
10. simpozij HRVATSKOG DRUŠTVA ZA ZAŠTITU OD ZRAČENJA
predavanje
15.04.2015-17.04.2015
Šibenik, Hrvatska