Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Forensic aspects of human blood evidence: From immunochromatographic test to STR profile (CROSBI ID 626222)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Horjan, Ivana ; Barbarić, Lucija ; Mršić, Gordan Forensic aspects of human blood evidence: From immunochromatographic test to STR profile // International Society for Applied Biological Sciences, Program and Abstracts, 9th ISABS Conference on Forensic, Anthropological Genetics and Mayo Clinic Lectures in Individualized Medicine / Kayser M., Ordog T., Vuk-Pavlović S., Primorac D., Schanfield M. (ur.). Zagreb: Grafički zavod Hrvatske, 2015. str. 108-108

Podaci o odgovornosti

Horjan, Ivana ; Barbarić, Lucija ; Mršić, Gordan

engleski

Forensic aspects of human blood evidence: From immunochromatographic test to STR profile

We investigated blood detection and STR profiles of simulated forensic evidentiary samples deposited on various substrates or treated with cleaning agents. Substrates with the trace deposited may itself introduce contaminants, while cleaning agents may alter the visible appearance of the trace. Furthermore, limited size of DNA samples can challenge the limits of PCR-based STR typing and question whether the trace yields sufficient good quality DNA for STR profiling. Immunochromatographic hemoglobin (ABAcard® Hematrace, HemDirect Hemoglobin) and glycophorin A (RSIDTM-Blood) tests were evaluated for sensitivity and specificity for the effects of substrates and the stain remover. Furthermore, potential negative effects on subsequent DNA analysis were tested. Data from this study support the notion that a full AmpFISTR®NGMTM DNA profile can be obtained from approximately 0.2 ng of starting DNA that equates to approximately 2 nL of fresh blood. The highest blood detection limit was observed for Hematrace® (approximately 2 pL of blood), HemDirect showed ten times lower sensitivity, while the lowest sensitivity was exhibited by RSIDTM-Blood (approximately 20 nL of blood). In addition, this test encountered the lowest efficacy in detection of blood treated with the stain remover containing active oxygen. None of the tested substrates (wood, metal, brick, and soil) neither stain remover influenced on test specificity, although soil substrate affected STR amplification.

forensic science; blood tests; sensitivity; specificity; DNA analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

108-108.

2015.

objavljeno

Podaci o matičnoj publikaciji

International Society for Applied Biological Sciences, Program and Abstracts, 9th ISABS Conference on Forensic, Anthropological Genetics and Mayo Clinic Lectures in Individualized Medicine

Kayser M., Ordog T., Vuk-Pavlović S., Primorac D., Schanfield M.

Zagreb: Grafički zavod Hrvatske

978-953-57695-1-4

Podaci o skupu

9th ISABS Conference on Forensic, Anthropological Genetics and Mayo Clinic Lectures in Individualized Medicine

poster

22.06.2015-26.06.2015

Bol, Hrvatska

Povezanost rada

Biologija