Broken Rotor Bar Detection in Induction Machines Using Measurement of Shaft Currents (CROSBI ID 483044)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Štefanko, Stjepan ; Kurtović, Ivan ; Bogut, Marijan ; Kovačević, Milan ; Momić, Milorad Broken Rotor Bar Detection in Induction Machines Using Measurement of Shaft Currents // IEEE SDEMPED 2001 - The 2001 IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives / Ambrozic, V., Filippetti, F. (ur.). Trst: Institute of Electrical and Electronics Engineers (IEEE), 2001. str. 623-626-x

Podaci o odgovornosti

Štefanko, Stjepan ; Kurtović, Ivan ; Bogut, Marijan ; Kovačević, Milan ; Momić, Milorad

engleski

Broken Rotor Bar Detection in Induction Machines Using Measurement of Shaft Currents

It is well known that magnetic asymmetries can result in a shaft current of the induction machine. This current can be measured with coil installed around the shaft. It will be shown that also a broken bar of squirrel-cage can affect the increase of shaft current and appearance of frequency (1±2s)f in the current spectrum. The tested machine was a 37 kW, 6-pole induction motor.

Induction machines; measurement; detection; broken bar; shaft current

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

623-626-x.

2001.

objavljeno

Podaci o matičnoj publikaciji

Ambrozic, V., Filippetti, F.

Trst: Institute of Electrical and Electronics Engineers (IEEE)

Podaci o skupu

The 2001 IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives

poster

01.09.2001-03.09.2001

Grado, Italija

Povezanost rada

Elektrotehnika