Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Impact of technical spraying factors on vertical liquid distribution with agromehanika AGP 440 axial fan sprayer (CROSBI ID 217947)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vujčić, Branimir ; Tadić, Vjekoslav ; Marković, Monika ; Lukinac Čačić, Jasmina ; Stošić, Miro ; Plaščak, Ivan Impact of technical spraying factors on vertical liquid distribution with agromehanika AGP 440 axial fan sprayer // Tehnički vjesnik : znanstveno-stručni časopis tehničkih fakulteta Sveučilišta u Osijeku, 22 (2015), 2; 367-373. doi: 10.17559/TV-20140331141848

Podaci o odgovornosti

Vujčić, Branimir ; Tadić, Vjekoslav ; Marković, Monika ; Lukinac Čačić, Jasmina ; Stošić, Miro ; Plaščak, Ivan

engleski

Impact of technical spraying factors on vertical liquid distribution with agromehanika AGP 440 axial fan sprayer

The influence of technical spraying factors on vertical distribution of liquid and air velocity was observed and measured with vertical patternator device. In research, Lechler yellow (TR 8002C) and red (TR 8004C) nozzles are used with two different sets of fan rotor blades (two different air velocities) at 540 rpm of PTO. The research was set as controlled three - factorial experiment (without the influence of weather factors) with 8 treatments in 4 repetitions, for each side of Agromehanika AGP 440 axial fan sprayer. Technical spraying factors (ISO nozzle number, settings of fan blades and spraying height) have a high significant impact (**) on the main properties of the research (vertical distribution of liquid and air velocity). By decreasing the ISO nozzle number and air velocity the increase of liquid deposit is found on vertical patternator and with the increase of measuring height a non-uniform distribution of liquid and air velocity is found. In addition, a non-uniform distribution of liquid and air velocity is established between the left and right sides of the machine. With regression analysis between the vertical distribution of liquid and air velocity on both sides of the machine, a statistically significant coherence is determined (left side of the machine: r = 0, 96 ; p < 0, 01 ; right side of the machine: r = 0, 97 ; p < 0, 01).

air velocity ; axial fan sprayer ; nozzle ; vertical liquid distribution ; vertical patternator

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

22 (2)

2015.

367-373

objavljeno

1330-3651

1848-6339

10.17559/TV-20140331141848

Povezanost rada

Poljoprivreda (agronomija), Prehrambena tehnologija

Poveznice
Indeksiranost