An Analitical Solution of Non­‐linear Equation of Chromatography and Its Application in Determination of Radioactive Strontium. (CROSBI ID 623502)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Grahek, Željko ; Coha, Ivana An Analitical Solution of Non­‐linear Equation of Chromatography and Its Application in Determination of Radioactive Strontium. // Tenth International Conference on Methods and Applications of Radioanalytical Chemistry. 2015

Podaci o odgovornosti

Grahek, Željko ; Coha, Ivana

engleski

An Analitical Solution of Non­‐linear Equation of Chromatography and Its Application in Determination of Radioactive Strontium.

The ideal linear model of chromatography can be used for the modelling of radionuclide sensor column in so called “equilibration based pre-­‐concentration mini-column sensor analysis for the determination of low level concentration of some elements and radionuclides in water”[1]. Egorov et all. used theoretical approach typical for linear equilibrium chromatography and applied theoretical solutions for frontal analysis to modelling (predict) column-­‐detector response (column with low number of theoretical plates ‐ solutions for the breakthrough curves). This approach is reasonable because at low concentration of element and "short" column, linear sorption isotherm and low number of theoretical plates are expected. However, if sample contains higher concentration of target element, deviation from linear condition is expected. In open literature, simple analytical solution doesn’t exist for non­‐ linear isotherm in case of frontal analysis. Therefore, in this paper authors will show how an analytical solution for parabolic isotherm can be obtained by combination of Cole-Hopf and Laplace transform. This solution will be used to predict sensor column response in previously mentioned sense. Difference between linear and non­‐linear solution with emphasis on prediction of Sr binding profile on Sr specific reins (Sr resin, SuperLig) and expected column response in case of low number of theoretical plates will be discussed. The advantages and limitations of non­‐linear solution will be shown through application to determine radioactive strontium in real samples.

Analitical solution; Chromatography; radioactive strontium; Sr resin

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2015.

objavljeno

Podaci o matičnoj publikaciji

Tenth International Conference on Methods and Applications of Radioanalytical Chemistry

Podaci o skupu

Tenth International Conference on Methods and Applications of Radioanalytical Chemistry - MARC X

poster

12.04.2015-17.04.2015

Kailua-Kona (HI), Sjedinjene Američke Države

Povezanost rada

Geologija, Kemija