Benefits and limitations of lab-on-a-chip method over reversed-phase high-performance liquid chromatography method in gluten proteins evaluation (CROSBI ID 217929)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Živančev, Dragan ; Horvat, Daniela ; Torbica, Aleksandra ; Belović, Miona ; Šimić, Gordana ; Magdić, Damir ; Đukić, Nevena Benefits and limitations of lab-on-a-chip method over reversed-phase high-performance liquid chromatography method in gluten proteins evaluation // Journal of Chemistry (Hindawi), 2015 (2015), 430328, 9. doi: 10.1155/2015/430328

Podaci o odgovornosti

Živančev, Dragan ; Horvat, Daniela ; Torbica, Aleksandra ; Belović, Miona ; Šimić, Gordana ; Magdić, Damir ; Đukić, Nevena

engleski

Benefits and limitations of lab-on-a-chip method over reversed-phase high-performance liquid chromatography method in gluten proteins evaluation

RP-HPLC (reversed-phase high-performance liquid chromatography) is widely used to determine the amounts of the different gluten protein types. However, this method is time-consuming, especially at early stages of wheat breeding, when large number of samples needs to be analyzed. On the other hand, LoaC (Lab-on-a- Chip) technique has the potential for a fast, reliable, and automatable analysis of proteins. In the present study, benefits and limitations of Lab- on-a-Chip method over RP-HPLC method in gluten proteins evaluation were explored in order to determine in which way LoaC method should be improved in order to make its results more compliant with the results of RP-HPLC method. Strong correlation (P ≤ 0.001) was found between numbers of HMW glutenin peaks determined by LoaC and RP-HPLC methods. Significant correlations (P ≤ 0.05) were obtained between percentages of HMW and LMW glutenin subunits calculated with regard to total HMW + LMW area. Even more significant correlation (P ≤ 0.001) was found when percentages of individual HMW areas were calculated with regard to total HMW. RP-HPLC method showed superiority in determination of gliadins since larger number and better resolution of gliadin peaks were obtained by this method.

lab-on-a-chip ; reversed-phase high-performance liquid chromatography ; gluten proteins

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

2015

2015.

430328

9

objavljeno

2090-9063

2090-9071

10.1155/2015/430328

Povezanost rada

Poljoprivreda (agronomija), Prehrambena tehnologija

Poveznice
Indeksiranost