Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Laboratory diagnostics of chronic kidney disease in Croatia: state of the art (CROSBI ID 217841)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Radišić Biljak, Vanja ; Honović, Lorena ; Matica, Jasminka ; Knežević, Branka ; Šimić-Vojak, Sanela Laboratory diagnostics of chronic kidney disease in Croatia: state of the art // Biochemia medica, 25 (2015), 73-83. doi: 10.11613/BM.2015.009

Podaci o odgovornosti

Radišić Biljak, Vanja ; Honović, Lorena ; Matica, Jasminka ; Knežević, Branka ; Šimić-Vojak, Sanela

engleski

Laboratory diagnostics of chronic kidney disease in Croatia: state of the art

Introduction: Early identification and management of chronic kidney disease (CKD) is highly cost- effective and can reduce the risk of kidney failure progression and cardiovascular disease. In 2014, the Joint Croatian Working Group (JCWG) for laboratory diagnostic of CKD on the behalf of Croatian society of medical biochemistry and laboratory medicine (CSMBLM) and Croatian chamber of medical biochemists (CCMB) conducted a survey across Croatian medical-biochemistry laboratories to assess the current practice in this area of laboratory medicine. The aim of this study was to present the data collected through the survey and to give insight about laboratory diagnostics of chronic kidney disease in Croatia. Materials and methods: An invitation to participate in the survey was sent to all Croatian medical- biochemistry laboratories (N = 196). The questionnaire was designed in a form of questions and statements, with possible multiple answers, comprising 24 questions. Results: The response rate was 80/196 (40.8%). 39 answers were from primary medical-biochemistry laboratories. 31/78 (0.40) laboratories measure creatinine with non- standardized method (uncompensated Jaffe method). 58/78 (0.74) of laboratories that measure creatinine do not report eGFR values. Similar number of laboratories (58/80, 0.73) do not measure urine albumin or protein. Conclusions: There is a large heterogeneity among Croatian laboratories regarding measuring methods, reporting units and reference intervals (cut-off values), both for creatinine and urine albumin or protein. The two key prerequisites for CKD screening, automatic reporting of eGFR and albuminuria or proteinuria assessment, are not implemented nationwide. There is a need for harmonization in laboratory diagnostics of CKD in Croatia.

survey ; chronic kidney disease ; estimated glomerular filtration rate (eGFR) ; albuminuria ; proteinuria ; creatinine ; harmonization

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

25

2015.

73-83

objavljeno

1330-0962

10.11613/BM.2015.009

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost