Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The Concept of an Integrated Performance Monitoring System for Promotion of Energy Awareness In Buildings (CROSBI ID 213961)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sučić, Boris, ; Anđelković, Aleksandar S. ; Tomšić, Željko The Concept of an Integrated Performance Monitoring System for Promotion of Energy Awareness In Buildings // Energy and buildings, 98 (2015), 82-91. doi: 10.1016/j.enbuild.2014.09.065

Podaci o odgovornosti

Sučić, Boris, ; Anđelković, Aleksandar S. ; Tomšić, Željko

engleski

The Concept of an Integrated Performance Monitoring System for Promotion of Energy Awareness In Buildings

In many modern buildings, different monitoring and control systems are used, but majority of them are not directly connected with the energy consumption optimisation. This paper presents a concept of an integrated performance monitoring system for promotion of energy awareness in buildings. The reference architecture of the envisioned system evolved from the traditional management structure, plan-do-check-act model. Traditional plan-do-check-act model has been upgraded with the integration of prediction engine, knowledge repository and modern scientific approaches for supporting energy awareness including early warning, optimisation and supervision. The proposed concept is constituted upon three modules: (1) data acquisition and processing, (2) knowledge repository, (3) performance monitoring system including prediction engine, consumption modelling, emissions calculation and decision support. The concept of three modules evolved from the idea to enrich existing solutions with the awareness about possible future abnormal situations and to enable preventive actions. Presented case study represents a repeatable application of the energy cost centres based modelling of energy consumption in educational and research buildings by using neuro-fuzzy modelling approach. Initial testing results are indicating the potential of electricity savings up to 15% enabled by visualisation and awareness about electricity consumption.

Performance monitoring; Performance indicators; Energy awareness

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

98

2015.

82-91

objavljeno

0378-7788

10.1016/j.enbuild.2014.09.065

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost