Influence of various factors on the dose of personnel during cardiology diagnostic (CROSBI ID 619951)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Milković, Đurđica ; Ranogajec-Komor, Mária ; Porcs-Makkay, László ; Knežević, Željka Influence of various factors on the dose of personnel during cardiology diagnostic // Proceedings of the Second International Conference on Radiation and Dosimetry in Various Fields of Research / Ristć, Goran (ur.). Niš: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2014. str. 207-210

Podaci o odgovornosti

Milković, Đurđica ; Ranogajec-Komor, Mária ; Porcs-Makkay, László ; Knežević, Željka

engleski

Influence of various factors on the dose of personnel during cardiology diagnostic

The aim of this work was the determination of staff exposure during coronary diagnostic procedure and the investigation of the effect of some factors (working method, fluoroscopy time, physical characteristics of cardiologist) on the doses to personnel. The measured doses in this work were compared to the doses measured by the National Dosimetry Service. The doses were measured with LiF:Mg, Cu, P thermoluminescence and phosphate glass radiophotoluminescence dosimetry systems (GD-352M) under and over the apron on the chest, on the left eye (eyebrow), left shoulder out of the apron, and left wrist of 3 cardiology doctors. Each doctor carried out 5 diagnostic coronary angiography procedures. The annual effective doses Eeff, calculated from the measured values as well as the equivalent doses to the eyes, were in all cases below the required dose limit (20 mSv/y ear). Significant differences of the effective doses were found among the three doctors in this study (15.5 mSv, 10.4 mSv, 8.7 mSv), as well as in the earlier results of the National Dosimetry Service (9.2 mSv, 4.6 mSv, 1.3 mSv). It was found that a single dosimeter under the apron performed by the National Service underestimates the Eeff as compared to the double dosimetry carried out in this study. The doses depend on many factors in coronary angiography, such as fluoroscopy time, complexity and number of examinations, experience of the doctor, feature of the doctor (height) and patient himself.

coronarography; radiation protection; scattered radiation; RPL dosimetry

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

207-210.

2014.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the Second International Conference on Radiation and Dosimetry in Various Fields of Research

Ristć, Goran

Niš: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu

978-86-6125-101-6

Podaci o skupu

Second International Conference on Radiation and Dosimetry in Various Fields of Research

predavanje

27.05.2014-30.05.2014

Niš, Srbija

Povezanost rada