Transient Analysis of Biological Tissue Modelled by Cole-Cole Dispersions Based on Numerical Inversion of Laplace Transform (CROSBI ID 619233)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Lacković, Igor ; Vyroubal, Darko ; Magjarević, Ratko
engleski
Transient Analysis of Biological Tissue Modelled by Cole-Cole Dispersions Based on Numerical Inversion of Laplace Transform
In this paper we present the calculation of current transients as a response to the applied voltage for a biological tissue whose complex permittivity was modelled by four Cole-Cole type dispersions. Initial formulation in the Laplace domain was transformed to the time domain by numerical inversion of Laplace transform using Stehfest algorithm. We analysed the influence of the voltage generator rise time and internal resistance on the current transient. Moreover, we analysed contributions of each individual dispersion on the current waveform. Due to its simplicity and good performance, Stehfest algorithm proved to be a very good choice for current transient calculation for multi Cole-Cole type dispersion materials like biological tissues.
dielectric tissue properties; Cole-Cole dispersions; current transient; numerical inversion of Laplace transform