Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

The Application of Ultrasound in Neuroendoscipic Procedures : First Results with the New Tool „NECUP-2“ (CROSBI ID 212759)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Jednačak, Hrvoje ; Paladino, Josip ; Miklić, Pavle ; Mrak, Goran ; Vukić, Miroslav ; Štimac, Tihomir ; Klarica, Marijan The Application of Ultrasound in Neuroendoscipic Procedures : First Results with the New Tool „NECUP-2“ // Collegium antropologicum, 35 (2011), S1; 45-49

Podaci o odgovornosti

Jednačak, Hrvoje ; Paladino, Josip ; Miklić, Pavle ; Mrak, Goran ; Vukić, Miroslav ; Štimac, Tihomir ; Klarica, Marijan

engleski

The Application of Ultrasound in Neuroendoscipic Procedures : First Results with the New Tool „NECUP-2“

In this paper, our experience with originally iconstructed Neurosurgical Endoscopic Contact Ultrasound Probe »NECUP-2« in neuroendoscopy is reported. Between June 1997 and June 2007, 132 neuroendoscopic procedures have been performed: 102 endoscopic thrid ventriculostomies (ETV), 15 arachnoid cysts and 5 intraventricular tumours operations. The »NECUP-2« was applied effectively in all cases in which blunt perforation was not possible: 38/102 ETV, 10/10 septostomies, 15/15 arachnoid cysts. In five cases of intraventricular tumours, neuroendoscopic procedure was combined with open microsurgery for tumour removal with preservation of vascular structures. There were no »NECUP-2« related complications. Of postoperative complications, we had liquorrhea (9 patients), and symptoms of meningitis (6 patients). In the follow-up period (6 months to 6 years), we had a patency rate of 80% (50/63 patients). All patients improved in clinical status. According to the first results, it seems that ultrasonic contact probe NECUP-2 presents a new device in neurosurgical armamentarium that can be used in various fields of neurosurgery. With minimal and controlled lesion that is produced at the tip of the probe, it can be used in highly demanding operations such as third ventriculostomy and tumour resection.

endoscopic neurosurgery ; high energy ultrasound ; third ventriculostomy

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

35 (S1)

2011.

45-49

objavljeno

0350-6134

Povezanost rada

Temeljne medicinske znanosti

Poveznice
Indeksiranost