Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Influence of air abrasion and sonic technique on microtensile bond strength of one-step self- etch adhesive on human dentin (CROSBI ID 210986)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Baraba, Anja ; Dukić, Walter ; Chieffi, Nicoletta ; Ferrari, Marco ; Pezelj Ribarić, Sonja ; Miletić, Ivana Influence of air abrasion and sonic technique on microtensile bond strength of one-step self- etch adhesive on human dentin // The Scientific World Journal, 2015:368745 (2015), 368745-1-368745-6. doi: 10.1155/2015/368745

Podaci o odgovornosti

Baraba, Anja ; Dukić, Walter ; Chieffi, Nicoletta ; Ferrari, Marco ; Pezelj Ribarić, Sonja ; Miletić, Ivana

engleski

Influence of air abrasion and sonic technique on microtensile bond strength of one-step self- etch adhesive on human dentin

The purpose of this in vitro study was to evaluate the microtensile bond strength of one- step self-etch adhesive to human dentin surface modified with air abrasion and sonic technique, and to assess the morphological characteristics of the pretreated dentin surface. The occlusal enamel was removed to obtain a flat dentin surface for thirty six human molar teeth. The teeth were randomly divided into three experimental groups (n=12 per group), according to the pretreatment of the dentin: 1) control group 2) air abrasion group and 3) sonic preparation group. Microtensile bond strength test was performed on a universal testing machine. Two specimens from each experimental group were subjected to SEM examination. There was no statistically significant difference in bond strength between the three experimental groups (p>0.05). Mean microtensile bond strength (MPa) values were: 35.3±12.8 for control group, 35.8±13.5 for air abrasion group and 37.7±12.0 for sonic preparation group. The use of air abrasion and sonic preparation with one-step self etch adhesive does not appear to enhance or impair microtensile bond strength in dentin.

air abrasion ; sonic technique ; microtensile bond strength ; self-etch

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

2015:368745

2015.

368745-1-368745-6

objavljeno

2356-6140

1537-744X

10.1155/2015/368745

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost