Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Kinetic and flow injection spectrophotometric determination of N-acetylcysteine ethyl ester based on the reduction of copper(II)-neocuproine (CROSBI ID 616116)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Kukoč-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biočić, Maja ; Radić, Njegomir Kinetic and flow injection spectrophotometric determination of N-acetylcysteine ethyl ester based on the reduction of copper(II)-neocuproine // Glasnik hemičara i tehnologa Bosne i Hercegovine = Bulletin of the Chemists and Technologists of Bosnia and Herzegovina / Korać, Fehim (ur.). 2014. str. 59-59

Podaci o odgovornosti

Kukoč-Modun, Lea ; Tsikas, Dimitrios ; Kraljević, Tomislav ; Biočić, Maja ; Radić, Njegomir

engleski

Kinetic and flow injection spectrophotometric determination of N-acetylcysteine ethyl ester based on the reduction of copper(II)-neocuproine

Kinetic spectrophotometric and flow injection methods of analysis were developed for the determination of a novel lipophilic cell-permeable cysteine derivative N-acetylcysteine ethyl ester (NACET). The proposed methods are based on a reduction reaction of Cu(II)-neocuproine reagent to Cu(I)-neocuproine by NACET in a Britton-Robinson buffer solution. The absorbance of the generated Cu(I)-neocuproine complex is measured at 458 nm. In the kinetic procedure a fixed time method was utilized for the construction of calibration graphs, and the recorded peak height was used as a quantitative variable in the flow injection procedure. A linear calibration graph was obtained from 1.0×10-6 to 1.0×10-4 mol L–1 of NACET by the use of the kinetic spectrophotometric method where the detection limit was 4.7×10-8 mol L-1. The linearity of the proposed flow injection method was obtained over the range 2.0×10-6 mol L-1 – 6.0×10-5 mol L-1 NACET, where the limit of detection was 2.7×10-7 mol L-1.

N-Acetylcysteine ethyl ester; Kinetic spectrophotometry; Fixed time method; Flow injection.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

59-59.

2014.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Glasnik hemičara i tehnologa Bosne i Hercegovine = Bulletin of the Chemists and Technologists of Bosnia and Herzegovina

Korać, Fehim

Sarajevo: Prirodno-matematički fakultet Sarajevo

0367-4444

Podaci o skupu

Congress of Chemists and Chemical Engineers of Bosnia and Herzegovina with International Participation

poster

10.10.2014-12.10.2014

Sarajevo, Bosna i Hercegovina

Povezanost rada

Kemija