Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Application Of The Temperature-Time Method For Measurement Of Local Power Losses In Transformer Steel Parts (CROSBI ID 615814)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Sitar, Robert ; Janić, Žarko Application Of The Temperature-Time Method For Measurement Of Local Power Losses In Transformer Steel Parts // 3rd International Colloquium Transformer Research and Asset Management. 2014

Podaci o odgovornosti

Sitar, Robert ; Janić, Žarko

engleski

Application Of The Temperature-Time Method For Measurement Of Local Power Losses In Transformer Steel Parts

Paper presents an application of temperature- time method for measurement of local losses in magnetic steel. Developed measurement system is described with focus on design of sensors and choice of instruments. Chosen equipment is tested on a DC circuit designed for measurement of losses in aluminum and copper conductors. Same measurement system is used for local loss measurement on magnetic steel rings. Measurement errors due to non-uniform loss distribution inside magnetic steel and heat dissipation to surrounding medium are analyzed and estimated.

local power loss; temperature-time method; magnetic steel; thermocouple; coupled calculation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2014.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

3rd International Colloquium Transformer Research and Asset Management

predavanje

15.07.2014-17.07.2014

Split, Hrvatska

Povezanost rada

Elektrotehnika