Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Comparative Analysis of Orbicularis Oculi Electromyogram and Voice Fundamental Frequency Variation in the Context of Acoustic Startle Response (CROSBI ID 614999)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Dropuljić, Branimir ; Mijić, Igor ; Petrinović, Davor ; Ćosić, Krešimir ; Jovanovic, Tanja Comparative Analysis of Orbicularis Oculi Electromyogram and Voice Fundamental Frequency Variation in the Context of Acoustic Startle Response // 5th IEEE International Conference on Cognitive Infocommunications. 2014. str. 149-154

Podaci o odgovornosti

Dropuljić, Branimir ; Mijić, Igor ; Petrinović, Davor ; Ćosić, Krešimir ; Jovanovic, Tanja

engleski

Comparative Analysis of Orbicularis Oculi Electromyogram and Voice Fundamental Frequency Variation in the Context of Acoustic Startle Response

This paper presents a comparison of two methods for measuring the acoustic startle response: orbicularis oculi (eyeblink) electromyogram (EMG), which is the conventional measure, and voice fundamental frequency (F0) variations as a consequence of laryngeal muscle innervations. A comparative analysis of the two approaches was performed using statistical methods, as well as system identification modeling using ARX, ARMAX, Output Error and Box-Jenkins models. For this purpose, an experiment was designed in which fourteen participants sustained constant phonation and acoustic startle stimuli of varying parameters were delivered at random time points during the phonation. Physiological signals, including eyeblink EMG, were acquired in parallel to voice recording. The comparative analysis showed that by increasing intensity of acoustic stimulus, response peak amplitudes of both: F0 variations and rectified and smoothed EMG responses increased as well. Therefore, voice F0 may be useful for startle response analysis when eyeblink EMG measurement is unavailable or impractical.

acoustic startle response ; EMG eyeblink reflex ; orbicularis oculi muscle ; voice fundamental frequency ; system identification modeling

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

149-154.

2014.

objavljeno

Podaci o matičnoj publikaciji

5th IEEE International Conference on Cognitive Infocommunications

Podaci o skupu

5th IEEE International Conference on Cognitive Infocommunications (CogInfoCom14)

predavanje

05.11.2014-07.11.2014

Vietri sul Mare, Italija

Povezanost rada

Elektrotehnika