Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Accuracy Analysis of Three-dimensional Articular- eminence Inclination Measuring Methods (CROSBI ID 614299)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Kranjčić, Josip ; Šlaus, Mario ; Peršić, Sanja ; Milardović Ortolan, Slađana ; Vodanović, Marin ; Vojvodić, Denis Accuracy Analysis of Three-dimensional Articular- eminence Inclination Measuring Methods // Journal of dental research. 2014. str. x-x

Podaci o odgovornosti

Kranjčić, Josip ; Šlaus, Mario ; Peršić, Sanja ; Milardović Ortolan, Slađana ; Vodanović, Marin ; Vojvodić, Denis

engleski

Accuracy Analysis of Three-dimensional Articular- eminence Inclination Measuring Methods

Objective: Due to the complex anatomical structure and function of the human temporomandibular joint (TMJ) different measurement methods were developed and introduced in TMJ. Therefore, the aim of this study was to determine and compare the accuracy between different methods used for the articular- eminence inclination (AEI) measurements. Method: The study was carried out on 30 human (aged 18 to 55 years) dry skulls from early medieval period excavated in Croatia. All selected skulls were without any damage in the measured area (articular eminence, fossa articularis, meatus acusticus externus, and orbitae). Silicone impressions of the articular eminence and fossa were made in order to ease the measurement of AEI. The measurements were performed using two dimensional digitalization of silicone impressions and VistaMetrix software, three-dimensional laser and three-dimensional optical digitalization with compatible softwares. AEI was measured in relation to the Frankfurt horizontal plane using two methods (“best fit line“ method and „fossa roof – eminence top“ method).The results obtained were statistically analyzed (descriptive statistics, paired-sample Student’s t-test, p<0.05). Result: Differences between two methods of AEI measurements (“best fit line“ method and „fossa roof – eminence top“ method) were statistically significant with significantly higher AEI values measured when using „best fit line“ method (p<0.05). Comparison of the results obtained by different methods of digitalization revealed that differences exist but mostly they were not statistically significant (p>0.05). Conclusion: Measurements carried out on silicone impressions of articular-eminence eased the measurement procedure and retained accuracy. Both three- dimensional measurement methods using different instruments (optical and laser) confirmed their accuracy revealing no significant difference. Measured AEI values obtained by „best fit line“ method were higher than values measured by „fossa roof – eminence top“ method, and greatly affected by the eminence height thus representing simplified but actual condylar path.

anthropology ; articular-eminence inclination ; prosthodontics ; TMJ ; masticatory muscles

Sažeci sa kongresa dostupni na mrežnoj stranici IADR Abstracts Archives

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

x-x.

2014.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Journal of dental research

0022-0345

1544-0591

Podaci o skupu

IADR/PER Congress

predavanje

10.09.2014-13.09.2014

Dubrovnik, Hrvatska

Povezanost rada

Arheologija, Dentalna medicina, Etnologija i antropologija

Poveznice
Indeksiranost