Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Method for experimental determination of beta-decay end point energies (CROSBI ID 92983)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Krečak, Zvonko ; Krčmar, Milica ; Kaučić, Stanko ; Ljubičić, Ante Method for experimental determination of beta-decay end point energies // Radiation physics and chemistry (1993), 61 (2001), 361-363-x

Podaci o odgovornosti

Krečak, Zvonko ; Krčmar, Milica ; Kaučić, Stanko ; Ljubičić, Ante

engleski

Method for experimental determination of beta-decay end point energies

In this paper we discuss a novel method based on using a beta-emitter source, a surface barrier silicon detector for beta-particles and two high purity germanium detectors for photons in a compact T geometry. A positron energy distribution was measured using a 58Co source and experimental positron end point energy determined by Fermi plot analyses being found to be in agreement with the literature.