Interpretation of complexometric titration data: An intercomparison of methods for estimating models of trace metal complexation by natural organic ligands (CROSBI ID 208445)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pižeta, Ivanka ; Sander, Sylvia ; Hudson, Robert ; Omanović, Dario ; Baars, Oliver ; Barbeau, Katherine ; Buck, Kristen ; Bundy, Randelle ; Carrasco, Gonzalo ; Croot, Peter et al. Interpretation of complexometric titration data: An intercomparison of methods for estimating models of trace metal complexation by natural organic ligands // Marine chemistry, 173 (2015), 3-24. doi: 10.1016/j.marchem.2015.03.006

Podaci o odgovornosti

Pižeta, Ivanka ; Sander, Sylvia ; Hudson, Robert ; Omanović, Dario ; Baars, Oliver ; Barbeau, Katherine ; Buck, Kristen ; Bundy, Randelle ; Carrasco, Gonzalo ; Croot, Peter ; Garnier, Cédric ; Gerringa, Loes ; Gledhill, Martha ; Hirose, Katsumi ; Kondo, Yoshiko ; Laglera, Luis ; Nuester, Jochen ; Rijkenberg, Micha ; Takeda, Shigenobu ; Twining, Benjamin ; Wells, Mona

engleski

Interpretation of complexometric titration data: An intercomparison of methods for estimating models of trace metal complexation by natural organic ligands

With the common goal of more accurately and consistently quantifying ambient concentrations of free metal ions and natural organic ligands in aquatic ecosystems, researchers from 15 laboratories that routinely analyze trace metal speciation participated in an intercomparison of statistical methods used to model the most widely-obtained type of experimental dataset, the complexometric titration. All were asked to apply statistical techniques that they felt comfortable using to model synthetic titration curves that are typical of those obtained by applying state-of-the-art electrochemical methods – anodic stripping voltammetry (ASV) and competitive ligand equilibration/adsorptive cathodic stripping voltammetry (CLE-ACSV) – to the analysis of natural waters. Herein, we compare our estimates for parameters describing the natural ligands, examine the accuracy of inferred ambient free metal ion concentrations ([Mf]), and evaluate the influence of the various methods and assumptions used in analyzing the data on these results. The ASV- type titrations were designed to test each participants’ ability to correctly describe the natural ligands present in a sample when provided with data free of measurement error, i.e., random noise. For the three virtual samples containing just one natural ligand, all participants were able to correctly identify the number of ligand classes present and accurately estimate their parameter values. For the four virtual samples containing two or three ligand classes, a few participants detected too few or too many classes and consequently reported inaccurate “measurements” of ambient [Mf]. Since the problematic results arose from human error rather than any specific method of analyzing the data, we recommend that analysts should make a practice of using one’s parameter estimates to generate simulated (back-calculated) titration curves for comparison to the original data. The root-mean squared difference between the fitted observations and simulated curves should be comparable to the expected error of the analytical method and upon visual inspection the distribution of residuals should be unskewed. Modeling the synthetic, CLE-ACSV-type titration dataset proved to be more challenging. The participants were provided with five distinct titration curves generated at different levels of competing ligand added (analytical windows) to the virtual sample. Random measurement error was also incorporated. Comparison of the submitted results was complicated by the differing interpretations of our task. Most adopted the provided “true” instrumental sensitivity in modeling the CLE- ACSV curves, but several estimated sensitivities using internal calibration, exactly as is required for actual samples. Since the fitted sensitivities were biased low, systematic biases in inferred ambient [Mf] and in estimated weak ligand (L2) concentrations resulted from their use. The main distinction between the mathematical approaches taken by participants lies in their choice of the speciation model equation/function, with its implicit definition of independent and dependent variables. In “direct modeling”, the dependent variable is the measured [Mf] (or Ip) and the total metal concentration ([M]T) considered independent. In other, much more widely used methods of analyzing titration data – classical linearization, best known as van den Berg/Ružić, and isotherm fitting by nonlinear regression, best known as the Langmuir or Gerringa methods – [Mf] is defined as independent and the dependent variable derived from a calculation that involves both [M]T and [Mf]. Close inspection of the biases and variability in the estimates of ligand parameters and in predictions of ambient [Mf] revealed that the best results were obtained by the first approach. Linear regression of transformed data yielded the largest bias and greatest variability, while non-linear isotherm fitting generated results with mean bias comparable to direct modeling, but also with greater variability. Participants that performed a unified analysis of ACSV titration curves at multiple detection windows for a sample improved their results regardless of the basic mathematical approach taken. Overall, the three most accurate sets of results were obtained using automated-unified analysis while the single most accurate set of results combined simultaneous calibration and parameter estimation. We therefore recommend that where sample volume and time permit, titration experiments for all natural water samples be designed to include two or more detection windows, especially for coastal and estuarine waters. It is vital that even more practical experimental designs for multi-window titrations be developed. In addition, while nearly every mathematical approach can prove to be adequate for some datasets, matrix-based equilibrium models are most naturally suited to the task for all datasets and can most easily handle the challenges encountered in this work, i.e., the cases where the added ligand in ACSV became titrated. The ProMCC program (Omanović et al., this issue) as well as the Excel Add-in based KINETEQL Multiwindow Solver spreadsheet (Hudson, 2014) have this capability and have been made available for public use as a result of this intercalibration exercise.

inter-comparison study ; synthetic data ; fitting ; simulation ; metal complexation by natural ligands ; speciation models ; voltammetric measurements ; multi-window data analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

173

2015.

3-24

objavljeno

0304-4203

10.1016/j.marchem.2015.03.006

Povezanost rada

Geologija, Kemija

Poveznice
Indeksiranost