Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols (CROSBI ID 207320)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Vučetić, Vlatko ; Šentija, Davor ; Sporiš, Goran ; Trajković, Nebojša ; Milanović, Zoran Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols // Acta clinica Croatica, 53 (2014), 2; 190-203

Podaci o odgovornosti

Vučetić, Vlatko ; Šentija, Davor ; Sporiš, Goran ; Trajković, Nebojša ; Milanović, Zoran

engleski

Comparison of ventilation threshold and heart rate deflection point in fast and standard treadmill test protocols

The purpose of this study was to compare two methods for determination of anaerobic threshold from two different treadmill protocols. Forty- eight Croatian runners of national rank (ten sprinters, fifteen 400-m runners, ten middle distance runners and thirteen long distance runners), mean age 21.7±5.1 years, participated in the study. They performed two graded maximal exercise tests on a treadmill, a standard ramp treadmill test (TSR, speed increments of 1 km•h-1 every 60 seconds) and a fast ramp treadmill test (TFR, speed increments of 1 km•h-1 every 30 seconds) to determine and compare the parameters at peak values and at heart rate at the deflection point (HR DP) and ventilation threshold (VT ). There were no significant differences between protocols (p>0.05) for peak values of oxygen uptake (VO2max, 4.48±0.43 and 4.44±0.45 L•min- 1), weight related VO2max (62.5±6.2 and 62.0±6.0 mL•kg-1•min-1), pulmonary ventilation (VE max, 163.1±18.7 and 161.3±19.9 L•min-1) and heart rate (HR max, 192.3±8.5 and 194.4±8.7 bpm) (TFR and TSR, respectively). Moreover, no significant differences between TFR and TSR where found for VT and HR DP when expressed as VO2 and HR . However, there was a significant effect of ramp slope on running speed at VO2max and at the anaerobic threshold (AnT) , independent of the method used (VT : 16.0±2.2 vs 14.9±2.2 km•h-1 ; HR DP: 16.5±1.9 vs 14.9±2.0 km•h-1 for TFR and TSR respectively). Linear regression analysis revealed high between-test and between-method correlations for VO2, HR and running speed parameters (r=0.78- 0.89, p<0.01). The present study has indicated that the VT and HR DP for running (VO2, ventilation, and heart rate at VT /HR DP) are independent of test protocol, while there is a significant effect of ramp slope on VT and HR DP when expressed as running speed. Moreover, this study demonstrates that the point of deflection from linearity of heart rate may be an accurate

Exercise test ; Anaerobic threshold ; Treadmill test ; Heart rate ; Pulmonary ventilation Correspondence

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

53 (2)

2014.

190-203

objavljeno

0353-9466

Povezanost rada

Kineziologija

Poveznice
Indeksiranost