Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Ion-Exchange Sample Displacement Chromatography as a Method for Fast and Simple Isolation of Low- and High-Abundance Proteins from Complex Biological Mixtures (CROSBI ID 206731)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šrajer Gajdošik, Martina ; Kovač, Spomenka ; Malatesti, Nela ; Müller, Egbert ; Josić, Djuro Ion-Exchange Sample Displacement Chromatography as a Method for Fast and Simple Isolation of Low- and High-Abundance Proteins from Complex Biological Mixtures // Food technology and biotechnology, 52 (2014), 1; 58-63

Podaci o odgovornosti

Šrajer Gajdošik, Martina ; Kovač, Spomenka ; Malatesti, Nela ; Müller, Egbert ; Josić, Djuro

engleski

Ion-Exchange Sample Displacement Chromatography as a Method for Fast and Simple Isolation of Low- and High-Abundance Proteins from Complex Biological Mixtures

Sample displacement chromatography (SDC) in reversed phase and ion-exchange modes was introduced at the end of 1980s. This chromatographic method was first used for preparative purification of synthetic peptides, and subsequently adapted for protein fractionation, mainly in anion-exchange mode. In the past few years, SDC has been successfully used for enrichment of low- and medium-abundance proteins from complex biological fluids on both monolithic and bulk chromatographic supports. If aqueous mobile phase is used with the application of mild chromatographic conditions, isolated proteins are not denatured and can also keep their biological activity. In this paper, the use of SDC in anion-exchange mode on a high-capacity chromatographic resin for separation of proteins from complex biological mixtures such as human plasma is demonstrated. By use of three and more columns coupled in series during sample application, and subsequent parallel elution of detached columns, additional separation of bound proteins was achieved. Highly enriched human serum albumin fraction and a number of physiologically active medium- and low-abundance proteins could be fractionated and detected by electrospray ionization tandem mass spectrometry (ESI-MS/MS) and matrix-assisted laser desorption/ ionization time-of-flight tandem mass spectrometry (MALDI- TOF/TOF-MS). The use of the aforementioned columns that can be sanitized with 1 M sodium hydroxide for further application of SDC in biotechnology and food technology was discussed.

sample displacement chromatography ; ion-exchange mode ; plasma proteins

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

52 (1)

2014.

58-63

objavljeno

1330-9862

Povezanost rada

Kemija, Biotehnologija, Prehrambena tehnologija

Poveznice
Indeksiranost