Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Benchmark analysis of EBR–II shutdown heat removal test SHRT–17 (CROSBI ID 611556)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Ivan Horvatovic ; Chirayu Batra ; Marco Cherubini ; Alessandro Petruzzi ; Francesco D’Auria ; Bajs, Tomislav Benchmark analysis of EBR–II shutdown heat removal test SHRT–17 // Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids / Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko (ur.). Zagreb: Hrvatsko nuklearno društvo, 2014. str. 125-1-125-10

Podaci o odgovornosti

Ivan Horvatovic ; Chirayu Batra ; Marco Cherubini ; Alessandro Petruzzi ; Francesco D’Auria ; Bajs, Tomislav

engleski

Benchmark analysis of EBR–II shutdown heat removal test SHRT–17

Coordinated Research Project (CRP) on EBR-II Shutdown Heat Removal Tests (SHRT) was established by International Atomic Energy Agency (IAEA). The aim of the project is to support and to improve validation of simulation tools and projects for Sodium-cooled Fast Reactors (SFR). The Experimental Breeder Reactor II (EBR-II) plant was a uranium metalalloy- fuelled liquid-metal-cooled fast reactor designed and operated by Argonne National Laboratory (ANL) for the U.S. Department of Energy at the Argonne-West site. In the frame of this project, benchmark analysis of one of the EBR-II shutdown heat removal tests, protected loss-of-flow transient (SHRT-17), has been performed at the Gruppo di Ricerca Nucleare San Piero a Grado (GRNSPG) in Pisa, Italy. The aim of this paper is to present modelling of EBR-II reactor design using RELAP-3D, and to present results of the transient analysis of SHRT- 17. Complete nodalization of the reactor was made from the beginning. Model is divided in primary side that contains core, pumps, reactor pool and, for this kind of reactor specific, Z pipe, and intermediate side that contains Intermediate Heat Exchanger (IHX). After achievement of acceptable steady-state results, transient analysis was performed. Starting from full power and flow, both the primary loop and intermediate loop coolant pumps were simultaneously tripped and the reactor was scrammed to simulate a protected loss-of-flow accident. In addition, the primary system auxiliary coolant pump that normally had an emergency battery power supply was turned off. Despite early rise of the temperature in the reactor, the natural circulation characteristics managed to keep it at acceptable leveles and cooled the reactor down safely at decay heat power levels. Thermal-hydraulics characteristics and plant behaviour was focused on prediction of natural convection cooling by evaluating the reactor core flow and temperatures and their comparison with experimental data that were provided by ANL. The plan is to improve the model in future with replacing current models of core and pool with 3D models, and, eventually, coupling with neutronic codes for more accurate results.

EBR-II; Sodium-cooled fast reactors; SHRT-17; RELAP-3D; protected loss-of-flow

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

125-1-125-10.

2014.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids

Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko

Zagreb: Hrvatsko nuklearno društvo

978-953-55224-6-1

Podaci o skupu

10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids

predavanje

01.06.2014-04.06.2014

Zadar, Hrvatska

Povezanost rada

Elektrotehnika