Hot Leg Streaming Calculation for Two-Loop PWR Plant (CROSBI ID 611510)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Grgić, Davor ; Fancev, Tomislav ; Benčik, Vesna ; Šadek, Siniša
engleski
Hot Leg Streaming Calculation for Two-Loop PWR Plant
Thermal stratification in hot leg pipe (often called hot leg streaming (HLS)) of PWR plant is caused by different heating of core fluid streams in fuel assemblies having different power production. Fluid streams having different temperature at core exit, after some mixing, enter hot leg pipe. Any perpendicular plane downstream hot leg pipe will have some kind of 2D temperature distribution and temperature measured by immersed Resistance Temperature Detectors (RTD) will depend on circumferential position and insertion depth of RTD detector. In order to get representative average temperature of the water typically 3 different circumferential measurement positions were used. The model for HLS calculation is developed based on core exit temperatures calculated by PARCS code and ANSYS-FLUENT CFD (Computational Fluid Dynamics) model of outlet plenum and hot legs. The scooping calculation was performed to determine HLS temperature profiles for NPP Krsko.
hot leg streaming; PARCS; FLUENT; temperature profiles
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
151-1-151-18.
2014.
nije evidentirano
objavljeno
978-953-55224-6-1
Podaci o matičnoj publikaciji
Proceedings of the 10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids
Čavlina, Nikola ; Grgić, Davor ; Pevec, Dubravko
Zagreb: Hrvatsko nuklearno društvo
Podaci o skupu
10th International Conference on Nuclear Option in Countries with Small and Medium Electricity Grids
predavanje
01.06.2014-04.06.2014
Zadar, Hrvatska