Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

The Impact of Boundary Conditions in Patient-Specific Coronary Blood Flow Simulation (CROSBI ID 610613)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Alena Uus, Panos Liatsis, Ronak Rajani, Lidija Mandic The Impact of Boundary Conditions in Patient-Specific Coronary Blood Flow Simulation // Proceedings of IWSSIP 2014 21st International Conference on Systems, Signals and Image processing / M. Muštra, D. Tralić, M. Grgić, B. Zovko-Cihlar (ur.). Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2014. str. 35-38

Podaci o odgovornosti

Alena Uus, Panos Liatsis, Ronak Rajani, Lidija Mandic

engleski

The Impact of Boundary Conditions in Patient-Specific Coronary Blood Flow Simulation

In patient-specific coronary blood flow modelling, the computational domain is defined as a 3D mesh of the major coronary arteries reconstructed from medical images. Blood flow itself is described through the flow equations that are defined over this computational domain and further solved by methods of computational fluid dynamics (CFD) in terms of pressure and velocity fields. One of the major factors determining the accuracy of the computed flow fields is the appropriate specification of flow conditions on the boundaries of the domain that represent the impact of the remaining (undefined) parts of the cardiovascular system (CVS). Boundary conditions (BC) can be assigned either explicitly or implicitly ; the difference being in the presence, or not of interaction between the domain (3D arteries) and the upstream/downstream vasculature. Application of more advanced implicit BC provides the means to model the adjustment of blood flow, depending on the downstream impedance and intramyocardial pressure, which results in “more realistic” computed blood fields. However, this also introduces a level of uncertainty, as blood flow in the required zones of CVS is unknown a priori and is generally difficult to measure in clinical practice, due to the highly invasive nature of the procedure. This work presents an analysis of the requirements for boundary conditions in the context of physiologically realistic simulations of coronary blood flow. This is elucidated through the analysis of 3D blood flow in patient-specific left coronary artery (LCA) cases. Moreover, a comparison between implicit and explicit BC and the methods of modelling patient-specific flow within the rest of CVS is provided.

blood flow simulations; CFD; boundary conditions; haemodynamics; downstream resistance; coronary artery disease; coronary blood flow

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

35-38.

2014.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of IWSSIP 2014 21st International Conference on Systems, Signals and Image processing

M. Muštra, D. Tralić, M. Grgić, B. Zovko-Cihlar

Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu

978-953-184-191-7

2157-8672

Podaci o skupu

IWSSIP 2014 21st International Conference on Systems, Signals and Image processing

predavanje

12.05.2014-15.05.2014

Dubrovnik, Hrvatska

Povezanost rada

Elektrotehnika