Is polyethylene the only cause of particle disease? (CROSBI ID 608146)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Kolundžić, Robert ; Orlić, Dubravko ; Smerdelj, Miroslav Is polyethylene the only cause of particle disease? // Journal of bone and joint surgery. American volume. 2004. str. 243-243

Podaci o odgovornosti

Kolundžić, Robert ; Orlić, Dubravko ; Smerdelj, Miroslav

engleski

Is polyethylene the only cause of particle disease?

The aim of the study is to present patients, to who uncemented conic, polyethylene acetabular components of total hip endoprosthesis (EP) Endler model, were implanted. The study tries to establish whether the cause of aseptic loosening of polyethylene acetabular components is the particle disease itself, as a reaction on polyethylene, or the causes may be found in other factors as well. In the period from 1985 to 1991, 100 patients (59 females and 41 males) were operated and 110 EP were implanted. The patients were followed from 10 to 16 years (median time – 12.47 years). In these study 72 patients with 80-implanted EP were evaluated (radiological, clinical and subjective evaluation). In 42 (52.50%) implanted Endler acetabular components subjective, radiological and clinical findings were very good or excellent. In 38 (47.40%) implanted acetabular components reacetabuloplasty was performed due to aseptic loosening ; in 22 of those components follow-up was 10 years and other 16 had follow-up of 11 to 16 years after the primary implantation. Conclusion: The results confirmed that aseptic loosening developed in one group of the patients (38 EP), but did not develop in the other group (42 EP) after long period. The comparison of postoperative biomechanic conditions which has not shown any statistically significant differences, led to conclusion that beside the main role of polyethylene and mechanic factors, immunological cell reaction and genetics can have an especially significant role. Necessities for new immunological studies in the application of total hip arthroplasty were stressed out by our results.

polyethylene ; particle disease ; total hip endoprosthesis

Selected Scientific Exhibits.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

243-243.

2004.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Journal of bone and joint surgery. American volume

0021-9355

1535-1386

Podaci o skupu

Annual Meeting of the American Academy of Orthopaedic Surgeons

predavanje

01.01.2004-01.01.2004

XX, XXX

Povezanost rada

nije evidentirano

Indeksiranost