Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Chemical vapour generation for tin determination in high-content calcium matrix by inductively coupled plasma atomic emission spectrometry (CROSBI ID 201938)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Rončević, Sanda ; Nemet, Ivan ; Pitarević Svedružić, Lovorka ; Medaković, Davorin Chemical vapour generation for tin determination in high-content calcium matrix by inductively coupled plasma atomic emission spectrometry // Croatica chemica acta, 87 (2014), 1; 17-22. doi: 10.5562/cca2259

Podaci o odgovornosti

Rončević, Sanda ; Nemet, Ivan ; Pitarević Svedružić, Lovorka ; Medaković, Davorin

engleski

Chemical vapour generation for tin determination in high-content calcium matrix by inductively coupled plasma atomic emission spectrometry

Chemical vapour generation by reduction with sodium tetraborohydride and coupled to inductively coupled plasma spectrometry (HG- ICP-AES) was examined for tin analysis in high- content calcium matrix samples. Comparison of calibration curves in aqueous and matrix- matched solution showed good linearity (R2 = 0.9951 – 0.9999) in the observed range of concentration. The effects of added calcium were established as attenuation of emission intensity for 3% at 224.605 nm and 235.484 nm and only 1% at 283.999 nm and 189.991 nm of tin lines. The best limit of detection, i.e. 1.9 mg L-1 in aqueous and 2.1 mg L-1 in matrix- matched solution were obtained at 189.991 nm. Method of standard addition was applied for the analysis of laboratory samples of high purity calcite and aragonite shell structures and it gave 0.11 µg g-1 and 0.17 µg g-1 of tin, respectively. The accuracy of method was tested by certified reference material (NCRC, MESS-3) and good recoveries (100.08%) were obtained in both calibration modes. Tin content was determined by HG-ICP-AES method using matrix- matched calibration in shell samples of Mytilus galloprovinicialis. The obtained values of tin content showed relatively flat distribution in shells along the coast (0.511 – 0.718 µg g-1). Higher concentrations were measured on several hotspots, especially fishing ports and harbours.

calcium matrix; hydride generation; icp-aes; tin; shell analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

87 (1)

2014.

17-22

objavljeno

0011-1643

10.5562/cca2259

Povezanost rada

Geologija, Kemija

Poveznice
Indeksiranost