Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Characterization of cysteamine self assembled on gold functionalized with nitrilotriacetic acid and evaluation of copper(II) binding capacity with adsorption transfer stripping voltammetry (CROSBI ID 201733)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kereković, Irena ; Milardović, Stjepan ; Palčić, Marina ; Grabarić, Zorana Characterization of cysteamine self assembled on gold functionalized with nitrilotriacetic acid and evaluation of copper(II) binding capacity with adsorption transfer stripping voltammetry // Journal of electroanalytical chemistry (1992), 724 (2014), 103-110. doi: 10.1016/j.jelechem.2014.04.017

Podaci o odgovornosti

Kereković, Irena ; Milardović, Stjepan ; Palčić, Marina ; Grabarić, Zorana

engleski

Characterization of cysteamine self assembled on gold functionalized with nitrilotriacetic acid and evaluation of copper(II) binding capacity with adsorption transfer stripping voltammetry

A self assembled monolayer of cysteamine (CA) was prepared on the surface of gold disc electrode and further modified with nitrilotriacetic acid (NTA). Modified Au/CA/NTA electrode was characterized with cyclic voltammetry and electrochemical impedance spectroscopy in presence of potassium hexacyanoferrate(II)/(III). Thus prepared electrode was tested for determination of Cu2+ with adsorption transfer stripping voltammetry. The binding of Cu2+ onto the modified electrode was successfully performed for a wide range of tested concentrations. Electrode response (Ip) was linearly proportional to -log c(Cu2+) with correlation coefficient R2 = 0.9767. The detection limit was M. The influence of interfering substances (Mg2+, Mn2+, Co2+ and Ni2+) was tested and it was found that Mg2+ does not interfere while Mn2+, Co2+ and Ni2+ show slight interference. Real-world testing of copper content in urine samples confirmed practical application of prepared sensor.

cysteamine; nitrilotriacetic acid; self assembled monolayer; adsorption transfer stripping voltammetry; electrochemical impedance spectroscopy

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

724

2014.

103-110

objavljeno

1572-6657

10.1016/j.jelechem.2014.04.017

Povezanost rada

Kemija

Poveznice
Indeksiranost