Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

First European JAK2-V617f interlaboratory quality control study carried out by the MPN&MPNR-Euronet (COST ACTION BM0902) (CROSBI ID 606346)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Pallisgaard, Niels ; Hasselbach, Hans Carl ; Cassinat, A. ; Kjaer, Lars ; Vorland, M. ; Dicker, F. ; Bellosillo, Beatriz ; Kristensen, T. ; Andersen, M. ; Lippert, Eric et al. First European JAK2-V617f interlaboratory quality control study carried out by the MPN&MPNR-Euronet (COST ACTION BM0902) // Haematologica. 2013. str. 115-115

Podaci o odgovornosti

Pallisgaard, Niels ; Hasselbach, Hans Carl ; Cassinat, A. ; Kjaer, Lars ; Vorland, M. ; Dicker, F. ; Bellosillo, Beatriz ; Kristensen, T. ; Andersen, M. ; Lippert, Eric ; Schwarz, Jiri ; Bryon, J. ; Naguib, D. ; Nomdedeu, J. ; Aggerholm, A. ; Wojtaszewska, Marzena ; Andrikovics, H ; Marušić, Maruška ; Ayala, R ; Leibundgut, E ; Samuelson, E ; Lode, L ; Girodon, F ; Percy, Melanie ; Hermouet, Sylvie

engleski

First European JAK2-V617f interlaboratory quality control study carried out by the MPN&MPNR-Euronet (COST ACTION BM0902)

Background: Analysis for the 1849G>T mutation in JAK2 (encoding JAK2- V617F) is routine in the diagnosis of myeloproliferative neoplasms (MPNs). The quantification of the allelic burden in JAK2- V617F positive patients is increasingly used to monitor treatment response of new targeted therapies as well as in transplanted patients. Aims:Across Europe the quantitative JAK2-V617F analysis is performed using a number of different assays and analysis platforms and calibration is therefore needed in order to standardise the results. Methods: Blood samples from 10 JAK2-V617F positive patients were aliquoted (1 ml) and sent out with overnight courier together with 4 reference DNA samples, a JAK2- V617F real time quantitative PCR (qPCR) reference assay and 4 DNA samples (blood samples were collected after informed consent according to the guidelines of the Danish Regional Science Ethics Committee). The reference DNAs were made from a 80 mL pool of normal donor DNA from blood samples by spiking four 10 fold dilutions of a 650 bp PCR product containing the JAK2-V617F mutation into 20 mL aliquots. The copy number of JAK2- V617F and JAK2 wild type in the 4 DNA pools were determined by qPCR and by digital PCR and the allelic ratios of JAK2- V617F were calculated to 75%, 23%, 2.9% and 0.2%, respectively. The qPCR reference assay (Larsen et al BJH 2007) that is recommended by the ELN for quantitative PCR (Jovanovic et al submitted) was prepared as 10 fold concentrated wild type and V617F mutant primer/probe mixtures. The 4 DNA samples contained either wild type DNA (normal donor DNA), V617F positive DNA (HEL cell line DNA), water (negative control) or normal donor DNA spiked with 1% JAK2- V617F. Two local JAK2-V617F positive DNA samples were also included and these were analysed as both non-diluted and ten fold diluted in order to identify a potential inhibition. Results: Twenty four laboratories from 13 European countries participated in the study. DNA from the 10 patient blood samples was purified according to local protocols. All samples were run in triplicates (or in duplicates in a few labs) with both the local JAK2-V617F assay and the supplied reference assay (384 qPCR wells per lab). Protocol information, Ct (PCR cycle) values and calculated copy numbers from the local assay were sent to Vejle for analysis (approximately 14, 000 data points). Although the reported copy numbers in the 10 patient samples varied between labs the percentage of JAK2-V617F alleles was rather consistent for both the local assay and the reference assay. All labs were able to indentify the 1% JAK2 V617F sample as positive when using the reference assay. However, in several labs the allelic burden of the 1% sample was not significantly different from the normal wild type DNA sample when using the local JAK2 assay indicating limited specificity due to nonspecific amplification Summary / Conclusion: In 24 labs across Europe the detection and quantification of the JAK2-V617F mutation was relatively consistent in patient samples with an allelic burden above 1%. For values below 1% the specificity and thereby the sensitivity of the analysis varied between labs and this was related to the JAK2- V617F assay used.

1849G>T mutation in JAK2; MPN; quantification of JAK2-V617F; COST ACTION BM0902

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

115-115.

2013.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Haematologica

0390-6078

Podaci o skupu

Congress of the European Hematology Association (18 ; 2013)

ostalo

13.06.2013-16.06.2013

Stockholm, Švedska

Povezanost rada

Temeljne medicinske znanosti, Biologija

Indeksiranost