Thermal Power Plant Stack Height Optimization

The SO2 environmental pollution in the Rijeka thermal power plant area and in nearby city of Rijeka is above regulatory recommended values. The optimization of stack height was performed in order to dimminish the pollution. Five stack heights are tested using Gaussian plume model with given digital elevation data of the area and meteorological one year hourly data.

air pollution modeling; Gaussian plume model; thermal power plant stack height optimization

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

353-354-x.

1998.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of 11th International DAAAM Symposium ‘Intelligent Manufacturing, Automation & Networking’

Katalinić, Branko

Beč:

Podaci o skupu

11th International DAAAM Symposium ‘Intelligent Manufacturing, Automation & Networking’

predavanje

21.10.1998-23.10.1998

Opatija, Hrvatska

Povezanost rada

Strojarstvo